								<item>
				<guid isPermaLink="false">04b394e261a672a1e1f47f50aba79257</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6617/#acomment-6699</link>
				<pubDate>Fri, 17 Apr 2026 02:19:27 +1200</pubDate>

									<content:encoded><![CDATA[<p>Bad luck days.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/camerongray/" data-bb-hp-profile="36" rel="nofollow">Cameron</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Fix one thing and something else shows up right after… feels like some calls just don’t want to end. You walk in thinking it’s a quick job and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">466deed944e2574070de8521927c1a89</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6568/#acomment-6577</link>
				<pubDate>Sat, 11 Apr 2026 19:37:51 +1200</pubDate>

									<content:encoded><![CDATA[<p>I started checking static pressure more because gauges alone were sending me the wrong direction on a few jobs.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/the_dylanparker/" data-bb-hp-profile="9" rel="nofollow">Dylan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Ran into a system today where suction pressure looked low so it seemed like a charge issue at first, but after checking a bit more it turned out to [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">6aaf1948700dbfc69d3d7e43489e4285</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6538/#acomment-6544</link>
				<pubDate>Wed, 08 Apr 2026 06:17:31 +1200</pubDate>

									<content:encoded><![CDATA[<p>Google ads + LSA.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/fabio_bianchi_53/" data-bb-hp-profile="65" rel="nofollow">Fabio</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Thinking about outsourcing SEO/marketing but hard to tell who actually delivers vs who just sends reports every month. Anyone here had a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">927316be23523e125910c361a324a2df</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6255/#acomment-6282</link>
				<pubDate>Wed, 11 Mar 2026 12:47:11 +1300</pubDate>

									<content:encoded><![CDATA[<p>We use dispatch software so I can see when they start and finish jobs. That’s enough for me.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ethan-carter21/" data-bb-hp-profile="96" rel="nofollow">Ethan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> For the guys running crews out in the field, how do you handle downtime when the board gets slow? I’ve been wondering how others keep their [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">49db012a50f88c06406f4e7392eaefea</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6271/#acomment-6274</link>
				<pubDate>Wed, 11 Mar 2026 09:45:46 +1300</pubDate>

									<content:encoded><![CDATA[<p>Use the green if it’s spare and call it a day.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/tyler_b/" data-bb-hp-profile="22" rel="nofollow">Tyler</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a>  					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4c318b780cf6bb0cee2acd361e049527</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6218/#acomment-6221</link>
				<pubDate>Sat, 21 Feb 2026 06:47:01 +1300</pubDate>

									<content:encoded><![CDATA[<p>Older homes sometimes had remodels where walls were moved and vents just got forgotten.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas-taylor/" data-bb-hp-profile="44" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Just closed on a house built in the 1920s and the furnace looks pretty new installed around 2022 from what I can tell. While walking through [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">6cf8a1dc3580a8f9ab407f8e82fa3667</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6155/#acomment-6186</link>
				<pubDate>Thu, 19 Feb 2026 09:26:37 +1300</pubDate>

									<content:encoded><![CDATA[<p>Reputation is built on the jobs nobody sees the callbacks you handle quietly.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/graysonwest_official/" data-bb-hp-profile="103" rel="nofollow">Grayson</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Most customers won’t remember the exact number on the invoice a year from now.
But they’ll remember if you showed up when you said you would, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f1e1dab156f828500655eccac7e57ac2</guid>
				<title>Benjamin posted an update in the group Troubleshooting &#038; Repairs: Hi All,</title>
				<link>https://hvachub.co/news-feed/p/6169/</link>
				<pubDate>Thu, 19 Feb 2026 04:09:04 +1300</pubDate>

									<content:encoded><![CDATA[<p>Hi All,</p>
]]></content:encoded>
				
									<slash:comments>11</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">12c3f8d2cc395593fc17ddee7bad9535</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5847/#acomment-5861</link>
				<pubDate>Wed, 11 Feb 2026 04:29:46 +1300</pubDate>

									<content:encoded><![CDATA[<p>Any chance it’s a cracked sensor lead that opens up when warm?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jamesrichard/" data-bb-hp-profile="77" rel="nofollow">James</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Flame rectification dropping below spec once cabinet temp rises past 120°F.
Runs fine cold, problems show up after it’s been on a while.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">165d878ff6f5a9051ebca89120ad3d6f</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5747/#acomment-5767</link>
				<pubDate>Sun, 08 Feb 2026 08:28:37 +1300</pubDate>

									<content:encoded><![CDATA[<p>That thing’s been choked for a long time. Amazing it ran at all with that coil.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jules_51/" data-bb-hp-profile="63" rel="nofollow">Jules</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> I’m sure this thing cooled great… before the coil turned into a dust blanket and airflow became optional.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c03423cb431b30fb174544fe23284489</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5627/#acomment-5655</link>
				<pubDate>Thu, 05 Feb 2026 21:02:35 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yeah, that’s what it’s starting to look like now.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hello All,					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">12fdc81ae8f4b8328efb4bf4c4d2e160</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5627/#acomment-5651</link>
				<pubDate>Thu, 05 Feb 2026 17:07:21 +1300</pubDate>

									<content:encoded><![CDATA[<p>Exactly.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hello All,					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">926081207eb5de42ab8b9de6415825a5</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5627/#acomment-5641</link>
				<pubDate>Thu, 05 Feb 2026 12:51:54 +1300</pubDate>

									<content:encoded><![CDATA[<p>Hope so. Right now it just feels like starting over overnight.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hello All,					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">80e58991d700f5498a278f8dfa843178</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5627/#acomment-5633</link>
				<pubDate>Thu, 05 Feb 2026 11:17:05 +1300</pubDate>

									<content:encoded><![CDATA[<p>Gonna slow it down before I break what’s left.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hello All,					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">cc5fa11d81994a120eb3ffdd7d2edc3f</guid>
				<title>Benjamin posted an update in the group HVAC Installation Best Practices: Hello All,</title>
				<link>https://hvachub.co/news-feed/p/5627/</link>
				<pubDate>Thu, 05 Feb 2026 09:32:14 +1300</pubDate>

									<content:encoded><![CDATA[<p>Hello All,</p>
]]></content:encoded>
				
									<slash:comments>12</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">8844a143d729823f8178dbce94c9eecc</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5439/#acomment-5441</link>
				<pubDate>Sat, 31 Jan 2026 01:11:48 +1300</pubDate>

									<content:encoded><![CDATA[<p>We looked into outsourcing takeoffs early on but honestly the back-and-forth killed it for us. By the time revisions were done, I could’ve finished it myself.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hello					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">31695d6a2dacba6fbecf6bd36d5d3b41</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4739/#acomment-4763</link>
				<pubDate>Sat, 17 Jan 2026 07:05:13 +1300</pubDate>

									<content:encoded><![CDATA[<p>We started tracking callbacks per unit age. Once a system crosses a certain line, we stop pretending it’s maintenance and start calling it risk management.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liam_brooks/" data-bb-hp-profile="53" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Opened this unit up today to see how far we can push it.
It’s working, but if it drops mid-week the downtime will hurt more than the repair [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">64cd616c292bc128158f682a390b202c</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4633/#acomment-4662</link>
				<pubDate>Wed, 14 Jan 2026 19:07:02 +1300</pubDate>

									<content:encoded><![CDATA[<p>Oil doesn’t travel alone. If it’s outside the system, refrigerant made the trip with it.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Had this condenser open today while chasing a capacity issue.
Pressures weren’t screaming low, superheat was borderline acceptable, but something [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">029c61efefa56a1d7fca6dd3955e76ab</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4633/#acomment-4660</link>
				<pubDate>Wed, 14 Jan 2026 17:07:05 +1300</pubDate>

									<content:encoded><![CDATA[<p>Nitrogen first. If it holds cold but drops hot, we’ll isolate the joint and rework it. No sense guessing.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Had this condenser open today while chasing a capacity issue.
Pressures weren’t screaming low, superheat was borderline acceptable, but something [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">81c39660aaaeb372d2527b575ce936d2</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4633/#acomment-4658</link>
				<pubDate>Wed, 14 Jan 2026 15:11:13 +1300</pubDate>

									<content:encoded><![CDATA[<p>Gravity and time… undefeated duo in HVAC.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Had this condenser open today while chasing a capacity issue.
Pressures weren’t screaming low, superheat was borderline acceptable, but something [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5087692dfb0489176b339c66c04603c5</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4633/#acomment-4656</link>
				<pubDate>Wed, 14 Jan 2026 13:16:38 +1300</pubDate>

									<content:encoded><![CDATA[<p>And somehow always the ones that just needed a top-off the last three summers.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Had this condenser open today while chasing a capacity issue.
Pressures weren’t screaming low, superheat was borderline acceptable, but something [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">989eca4aae3a1c19ce53a9a2311b8857</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4633/#acomment-4648</link>
				<pubDate>Wed, 14 Jan 2026 10:57:42 +1300</pubDate>

									<content:encoded><![CDATA[<p>That’s why I stopped trusting one-time pressure tests on older installs. Heat cycles expose everything eventually.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Had this condenser open today while chasing a capacity issue.
Pressures weren’t screaming low, superheat was borderline acceptable, but something [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4c995ac3c6e04018a448f073d1130a1e</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4633/#acomment-4640</link>
				<pubDate>Wed, 14 Jan 2026 09:21:52 +1300</pubDate>

									<content:encoded><![CDATA[<p>Gauges were fine enough but the unit history wasn’t. Numbers don’t show what time does.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Had this condenser open today while chasing a capacity issue.
Pressures weren’t screaming low, superheat was borderline acceptable, but something [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a0c84d4f9123992ecfb557c292a00490</guid>
				<title>Benjamin posted an update in the group Troubleshooting &#038; Repairs: Had this condenser open today while chasing a [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/4633/</link>
				<pubDate>Wed, 14 Jan 2026 07:39:05 +1300</pubDate>

									<content:encoded><![CDATA[<p>Had this condenser open today while chasing a capacity issue.<br />
Pressures weren’t screaming low, superheat was borderline acceptable, but something didn’t sit right.<br />
Noticed light oil staining around the service valve and flare area &#8211; nothing dramatic, no active bubbling, but enough dust stuck to it to know it’s been there a while. One of&hellip;<span class="activity-read-more" id="activity-read-more-4633"><a href="https://hvachub.co/news-feed/p/4633/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>12</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">9741abc5415255e81c8edefacf60b669</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4370/#acomment-4381</link>
				<pubDate>Thu, 08 Jan 2026 05:16:59 +1300</pubDate>

									<content:encoded><![CDATA[<p>If the numbers look good but your gut doesn’t, trust the gut.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/davida_costa/" data-bb-hp-profile="82" rel="nofollow">Davida</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> <p>The hardest issues are the ones where nothing is technically wrong.</p>					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">823334d6edf2c22302f9066a3afdc1e1</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4334/#acomment-4345</link>
				<pubDate>Wed, 07 Jan 2026 01:16:49 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yep. It’s running the version it prefers.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Spent time looking at a dual-circuit water-cooled chiller where, on paper, both circuits should behave the same. Same room, same water [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">b78ef048fff1ab615d585f854622d4c6</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4334/#acomment-4343</link>
				<pubDate>Wed, 07 Jan 2026 00:36:10 +1300</pubDate>

									<content:encoded><![CDATA[<p>Mechanical issues don’t announce themselves-they just shift behavior.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Spent time looking at a dual-circuit water-cooled chiller where, on paper, both circuits should behave the same. Same room, same water [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">17d8108cd0d934fed8183ce831687217</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4334/#acomment-4341</link>
				<pubDate>Wed, 07 Jan 2026 00:14:01 +1300</pubDate>

									<content:encoded><![CDATA[<p>Pretty much. Same job title, very different effort.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Spent time looking at a dual-circuit water-cooled chiller where, on paper, both circuits should behave the same. Same room, same water [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e8982bb2813f063e6d4e6d8bae12ac58</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4334/#acomment-4340</link>
				<pubDate>Wed, 07 Jan 2026 00:10:24 +1300</pubDate>

									<content:encoded><![CDATA[<p>Sometimes you learn more by listening than logging.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Spent time looking at a dual-circuit water-cooled chiller where, on paper, both circuits should behave the same. Same room, same water [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5aa9be6d5e65bad433cbd916731afc33</guid>
				<title>Benjamin posted an update in the group HVAC Contractors &#038; Subcontractors: Spent time looking at a dual-circuit water-cooled [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/4334/</link>
				<pubDate>Tue, 06 Jan 2026 22:34:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>Spent time looking at a dual-circuit water-cooled chiller where, on paper, both circuits should behave the same. Same room, same water side, similar piping runs &#8211; yet in operation, one circuit carries load smoothly while the other cycles more than expected.<br />
Charge and controls check out. The difference feels tied to something mechanical or on&hellip;<span class="activity-read-more" id="activity-read-more-4334"><a href="https://hvachub.co/news-feed/p/4334/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>8</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">41e2b4e9d45180484a14a875bbfbee9c</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4280/#acomment-4285</link>
				<pubDate>Sat, 03 Jan 2026 18:44:53 +1300</pubDate>

									<content:encoded><![CDATA[<p>Had something similar where stratification in the mixing section fooled everything.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ethan-carter21/" data-bb-hp-profile="96" rel="nofollow">Ethan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Mixed air temperature keeps drifting even though outside air and return air readings stay steady. Economizer isn’t stuck, but indoor humidity [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f60880792140d63562f3f08751d44ccf</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4187/#acomment-4188</link>
				<pubDate>Thu, 01 Jan 2026 19:36:04 +1300</pubDate>

									<content:encoded><![CDATA[<p>I hate jobs like this. Everything “works” but you know it’s lying.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/j_cooper818/" data-bb-hp-profile="13" rel="nofollow">Jordan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> <p>Walked into this job thinking it would be a quick check. Unit was running, no alarms, temps looked fine at first glance. But the space [&hellip;]</p>					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bf209ab8fd4a0f0d4ea5a9f93c81f56a</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3974/#acomment-3975</link>
				<pubDate>Wed, 24 Dec 2025 13:42:27 +1300</pubDate>

									<content:encoded><![CDATA[<p>Momentary power dips to the control circuit can cause this without affecting the main feed.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/mr_owenmiller/" data-bb-hp-profile="19" rel="nofollow">Owen</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Seeing a chiller micro-cycle because the enable signal drops out for a few milliseconds.
Not long enough to alarm, but enough to reset [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">6dac3be7a48db0ccb71453594fa8c285</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3923/#acomment-3928</link>
				<pubDate>Mon, 22 Dec 2025 07:08:45 +1300</pubDate>

									<content:encoded><![CDATA[<p>We’ve started adding access issues to our service notes now.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/alessandro_rossi_88/" data-bb-hp-profile="28" rel="nofollow">Alessandro</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Showed up to a site where the unit room was technically accessible, but stacked with boxes, ladders, and random storage.
Spent more [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">51da8b967ce6f88c9526b17b1cf8beba</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3624/#acomment-3634</link>
				<pubDate>Mon, 15 Dec 2025 09:44:56 +1300</pubDate>

									<content:encoded><![CDATA[<p>I’ve only been watching space temps. Need to check LAT.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Cooling’s doing its job on temperature, but RH keeps creeping up anyway.
Feels like dehumidification is getting undercut somewhere &#8211; airflow, coil, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">556b6a5b0dc3f36b939addb39f80d432</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3624/#acomment-3632</link>
				<pubDate>Mon, 15 Dec 2025 09:44:56 +1300</pubDate>

									<content:encoded><![CDATA[<p>Occupants are definitely not impressed.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Cooling’s doing its job on temperature, but RH keeps creeping up anyway.
Feels like dehumidification is getting undercut somewhere &#8211; airflow, coil, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c879ca02235d8188ff5acb5262f98bcd</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3624/#acomment-3630</link>
				<pubDate>Mon, 15 Dec 2025 09:44:55 +1300</pubDate>

									<content:encoded><![CDATA[<p>OA position might be drifting. I’ll verify minimums.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Cooling’s doing its job on temperature, but RH keeps creeping up anyway.
Feels like dehumidification is getting undercut somewhere &#8211; airflow, coil, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ff0f9df4c5b2048a19663f9fe906df3a</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3624/#acomment-3628</link>
				<pubDate>Mon, 15 Dec 2025 09:44:54 +1300</pubDate>

									<content:encoded><![CDATA[<p>That’s the plan for tomorrow. Appreciate the input.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Cooling’s doing its job on temperature, but RH keeps creeping up anyway.
Feels like dehumidification is getting undercut somewhere &#8211; airflow, coil, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4c5ee62f33a82c55dc609574537e9fb7</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3624/#acomment-3626</link>
				<pubDate>Mon, 15 Dec 2025 09:44:54 +1300</pubDate>

									<content:encoded><![CDATA[<p>Didn’t think about that angle. I’ll look at fan speed and CFM.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Cooling’s doing its job on temperature, but RH keeps creeping up anyway.
Feels like dehumidification is getting undercut somewhere &#8211; airflow, coil, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">fa0e232be19e2717c7487446b141f38f</guid>
				<title>Benjamin posted an update in the group HVAC Tools &#038; Equipment: Cooling’s doing its job on temperature, but RH keeps [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/3624/</link>
				<pubDate>Mon, 15 Dec 2025 09:44:53 +1300</pubDate>

									<content:encoded><![CDATA[<p>Cooling’s doing its job on temperature, but RH keeps creeping up anyway.<br />
Feels like dehumidification is getting undercut somewhere &#8211; airflow, coil, or reheat fighting it.</p>
]]></content:encoded>
				
									<slash:comments>10</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">1a440d470de2df2bd1116d67bc216964</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3574/#acomment-3577</link>
				<pubDate>Thu, 11 Dec 2025 21:48:33 +1300</pubDate>

									<content:encoded><![CDATA[<p>Could be the VAV transducers lagging behind the actual duct pressure change. Some of the older ones react way too slow.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jack-moore_15/" data-bb-hp-profile="83" rel="nofollow">Jack</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Seeing a weird one &#8211; when the supply fan ramps up, a few VAV boxes actually lose airflow for a moment.
CFM drops for a couple seconds like [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e73f67db99e0fac91179b3011a11e46b</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3555/#acomment-3562</link>
				<pubDate>Wed, 10 Dec 2025 19:36:50 +1300</pubDate>

									<content:encoded><![CDATA[<p>If the coil air side is good and CHW supply steady, then it’s almost always a water-side restriction or bad authority.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/nromero_52/" data-bb-hp-profile="61" rel="nofollow">Nicolas</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Got an AHU coil losing  every time the CHW pump VFD ramps down, even though the control valve shows 100% open.
Strainer’s clean, no air, CHW supply [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ed49d2a4f192de94738c8f9bbd6f60fc</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2989/#acomment-2992</link>
				<pubDate>Wed, 12 Nov 2025 19:59:24 +1300</pubDate>

									<content:encoded><![CDATA[<p>If it bleeds off that fast, it’s likely a collapsing secondary winding. Transformer could test fine open circuit but fail under load.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/j_cooper818/" data-bb-hp-profile="13" rel="nofollow">Jordan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Came across a strange one today &#8211; transformer keeps dropping voltage under load, but this time the fuse actually holds fine and the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f0864f532ddd4a8190b5636fa67a8c30</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2738/#acomment-2749</link>
				<pubDate>Thu, 30 Oct 2025 20:08:49 +1300</pubDate>

									<content:encoded><![CDATA[<p>Trane diagnostic codes make sense once you get familiar with their control boards. Print out the code chart and keep it in your van.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/m_carter/" data-bb-hp-profile="93" rel="nofollow">Mathew</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Honestly, I don’t get to work on Trane units very often.
Curious &#8211; who here works on them regularly?
Any good manuals, PDFs, or online resources [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">82d8fef90e88a1136e854e41d2b8dee0</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2691/#acomment-2696</link>
				<pubDate>Wed, 29 Oct 2025 13:56:22 +1300</pubDate>

									<content:encoded><![CDATA[<p>I’ve got senior techs who can fix anything mechanical but struggle with control systems.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/graysonwest_official/" data-bb-hp-profile="103" rel="nofollow">Grayson</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> If I’m honest, the toughest challenge these days isn’t finding new clients-it’s finding the right technicians.

Commercial systems have changed [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bfebe8b50fd45bdcee119e630229a91c</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2475/#acomment-2480</link>
				<pubDate>Sat, 18 Oct 2025 14:03:08 +1300</pubDate>

									<content:encoded><![CDATA[<p>ometimes the VFD settings are off after maintenance &#8211; double-check ramp curves and speed limits.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Noticed a weird drop in flow on one of the chilled water pumps in a large commercial system. The pump seems fine &#8211; no strange noises, amp draw [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a3e599c2f54a498af515b4358c567315</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2220/#acomment-2227</link>
				<pubDate>Fri, 10 Oct 2025 18:11:16 +1300</pubDate>

									<content:encoded><![CDATA[<p>I recommend checking lines during every maintenance visit &#8211; early detection is key.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/mason-smith_18/" data-bb-hp-profile="90" rel="nofollow">Mason</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Last week I visited a commercial site where the cooling system wasn’t performing efficiently. After checking, I noticed that several refrigerant [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">7ddc0ac783ba4ee156297a479045042e</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2186/#acomment-2191</link>
				<pubDate>Wed, 08 Oct 2025 06:09:02 +1300</pubDate>

									<content:encoded><![CDATA[<p>I had a similar issue once- replacing the TXV solved it immediately.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/et-walker07/" data-bb-hp-profile="11" rel="nofollow">Ethan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> I’m seeing unusual liquid floodback to the compressor on a system- suction superheat is way too low.

Not sure if it’s a TXV problem or a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">322f532e62cce3a073462cc1228591dd</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2158/#acomment-2169</link>
				<pubDate>Mon, 06 Oct 2025 18:23:43 +1300</pubDate>

									<content:encoded><![CDATA[<p>we could create a weekly Q&amp;A thread for troubleshooting tough HVAC issues.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Hi friends,

I just wanted to say &#8211; this community works best when everyone shares their wins, fails, and tips. Even a small [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8c2bc414ff7f8ea68d86259f51ea48fa</guid>
				<title>Benjamin posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1092/#acomment-1098</link>
				<pubDate>Wed, 23 Jul 2025 10:25:20 +1200</pubDate>

									<content:encoded><![CDATA[<p>Isolation pads and level concrete floor prevent vibrations-future-proofing serviceability.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ethan_anderson_17/" data-bb-hp-profile="72" rel="nofollow">Ethan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Just finished a dedicated compressor room: compressors on vibration pads, 3 ft clearance all around, inlet/exhaust ventilation, [&hellip;]					]]></content:encoded>
				
				