<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
		>

<channel>
	<title>HVAC Community Hub | Elijah | Activity</title>
	<link>https://hvachub.co/members/elijah-thomos/activity/</link>
	<atom:link href="https://hvachub.co/members/elijah-thomos/activity/feed/" rel="self" type="application/rss+xml" />
	<description>Activity feed for Elijah.</description>
	<lastBuildDate>Wed, 29 Apr 2026 10:07:49 +1200</lastBuildDate>
	<generator>https://buddypress.org/?v=2.18.0</generator>
	<language>en-US</language>
	<ttl>30</ttl>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>2</sy:updateFrequency>
		
								<item>
				<guid isPermaLink="false">49dcab7527465a209b0128e2e543c4e3</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6664/#acomment-6676</link>
				<pubDate>Thu, 16 Apr 2026 08:24:59 +1200</pubDate>

									<content:encoded><![CDATA[<p>Higher resistance at the contacts increases heat at that point, but more importantly it reduces the voltage available to the motor. Lower voltage &#8211; higher current draw &#8211; overheating. It’s a chain reaction.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/rob_vitale64/" data-bb-hp-profile="45" rel="nofollow">Robert</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Swapped a contactor today that looked fine at a glance, but under load it was dropping voltage across the contacts. Getting about 240V in, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">33b3ad50fcd063826235c08505c48887</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6583/#acomment-6587</link>
				<pubDate>Sun, 12 Apr 2026 02:10:09 +1200</pubDate>

									<content:encoded><![CDATA[<p>I used to rush more slowed down a bit and my callbacks dropped a lot.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/samuel-brown50/" data-bb-hp-profile="85" rel="nofollow">Samuel</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Callbacks are killing time over small misses lately. Anyone else dealing with this?					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5bcf18f1c2f1b30c307201e9295aab5d</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6405/#acomment-6416</link>
				<pubDate>Fri, 20 Mar 2026 14:51:23 +1300</pubDate>

									<content:encoded><![CDATA[<p>Always purge. Not because of contamination risk on small repairs because it&#8217;s a habit. The day you start making exceptions is the day you forget on a job where it actually matters</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas_reed/" data-bb-hp-profile="15" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Nitrogen purge when brazing. Every time. No exceptions.
That&#8217;s what we&#8217;re taught and honestly that&#8217;s what I believe. But I&#8217;ve had this argument [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">769367b96faa9163c6644a998d3d4405</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6369/#acomment-6386</link>
				<pubDate>Thu, 19 Mar 2026 17:45:32 +1300</pubDate>

									<content:encoded><![CDATA[<p>Quoted a full TXV replacement on a system with high superheat. Customer approved it. Went back to do the job, popped the panel, found the sensing bulb had just fallen off the suction line. Strapped it back on. System ran perfect. Charged for the diagnostic only and wanted to retire on the spot.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/mr_owenmiller/" data-bb-hp-profile="19" rel="nofollow">Owen</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Worst misdiagnosis you&#8217;ve made that turned out to be something embarrassingly simple.
We&#8217;ve all been there. Spent an hour or two [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e4701a206108238f91842de0a7a9a94d</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6326/#acomment-6333</link>
				<pubDate>Tue, 17 Mar 2026 12:36:27 +1300</pubDate>

									<content:encoded><![CDATA[<p>The ones that only happen when you&#8217;re not watching are the worst kind.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Three hours. Checked the board, checked the contactor, checked the capacitor, checked every connection in the system twice.
Everything [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">059c07d11e85bb7db606298cf706a5a3</guid>
				<title>Elijah posted an update in the group HVAC Installation Best Practices: Three hours. Checked the board, checked the [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/6326/</link>
				<pubDate>Tue, 17 Mar 2026 09:53:16 +1300</pubDate>

									<content:encoded><![CDATA[<p>Three hours. Checked the board, checked the contactor, checked the capacitor, checked every connection in the system twice.<br />
Everything tested fine. Every single time.<br />
Turned out to be a nick in the thermostat wire inside the wall. Only shorts when the front door slams hard enough to flex the drywall.<br />
I found it because the customer&#8217;s kid ran&hellip;<span class="activity-read-more" id="activity-read-more-6326"><a href="https://hvachub.co/news-feed/p/6326/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>9</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">d6c316c7e4dd7c8b2491fbdc4d43145b</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6160/#acomment-6170</link>
				<pubDate>Thu, 19 Feb 2026 05:01:42 +1300</pubDate>

									<content:encoded><![CDATA[<p>Did they at least give you enough rod? Or you cutting and coupling all day?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> 30’ ceilings + scissor lift all day.
Trying to keep the trunk straight while dodging steel and sprinkler lines.
Whoever drew this on paper [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5218e03ea70af73c7f6954e68ea19874</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6088/#acomment-6105</link>
				<pubDate>Sat, 14 Feb 2026 15:29:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>You sure it’s oil and not just dirty evap coils? Residential maintenance is rough these days.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/henry_mitchell_71/" data-bb-hp-profile="49" rel="nofollow">Henry</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Seeing more systems lately that just run longer and feel weaker.
Makes me wonder how much oil fouling gets ignored in residential.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c915afa98d1e1df7f42a03b5bc515e16</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5984/#acomment-6023</link>
				<pubDate>Fri, 13 Feb 2026 11:45:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>True. Every tool has weak points. End of the day it’s not analog vs digital it’s whether the tech understands the numbers.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> There’s a difference between it feels cold and actually checking what the system is doing.
Pressures, temps, airflow  that’s what tells the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">fbb5163fa1e1a1fcc66be2a560e04487</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5970/#acomment-5989</link>
				<pubDate>Fri, 13 Feb 2026 07:17:18 +1300</pubDate>

									<content:encoded><![CDATA[<p>Fieldpiece quietly stopped supporting the 3 series. Found that out the hard way last year.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/dan_clarke_official/" data-bb-hp-profile="39" rel="nofollow">Daniel</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Has anyone successfully added R-454B or R-32 to the SMAN 360, or is that only supported on the SM380V? I’ve been digging through updates and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">15aedabfb85b0a9cafd8cd441b9cbb9e</guid>
				<title>Elijah posted an update in the group HVAC Installation Best Practices: There’s a difference between it feels cold and actually [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/5984/</link>
				<pubDate>Fri, 13 Feb 2026 06:23:10 +1300</pubDate>

									<content:encoded><![CDATA[<p>There’s a difference between it feels cold and actually checking what the system is doing.<br />
Pressures, temps, airflow  that’s what tells the real story.<br />
If you’re not measuring it, you’re just guessing.<br />
Before summer hits hard, make sure your unit is actually performing the way it should.<br />
If you want it even more trade-group style and less&hellip;<span class="activity-read-more" id="activity-read-more-5984"><a href="https://hvachub.co/news-feed/p/5984/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>8</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">fea718c579ec7ea4ea707accdf3eb174</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5771/#acomment-5797</link>
				<pubDate>Sun, 08 Feb 2026 18:33:52 +1300</pubDate>

									<content:encoded><![CDATA[<p>Honestly the biggest jump for me was getting out of the truck part time. Even one less day in the field made a difference.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/tyler_b/" data-bb-hp-profile="22" rel="nofollow">Tyler</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Mid-size market, roughly 900k population in our service area. Median household income around low 70s. We’re running 2 trucks plus me still in [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">cbf377ec12835391b243b777adcb2ec2</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5514/#acomment-5543</link>
				<pubDate>Tue, 03 Feb 2026 18:45:42 +1300</pubDate>

									<content:encoded><![CDATA[<p>If it’s minor, adjust. Once blades are distorted, replacement’s usually cleaner.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Damper blades are bent and out of alignment. Even with the actuator calling, airflow isn’t modulating evenly, which explains the uneven [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">fabbb240987077b5c00a9454f98340ea</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5514/#acomment-5541</link>
				<pubDate>Tue, 03 Feb 2026 16:45:05 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yeah, definitely not their first problem.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Damper blades are bent and out of alignment. Even with the actuator calling, airflow isn’t modulating evenly, which explains the uneven [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">95d661e83e3c51fd394581b8227a6210</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5514/#acomment-5537</link>
				<pubDate>Tue, 03 Feb 2026 14:50:25 +1300</pubDate>

									<content:encoded><![CDATA[<p>True.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Damper blades are bent and out of alignment. Even with the actuator calling, airflow isn’t modulating evenly, which explains the uneven [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">18c8ee22f8d2653ba781ba32465a9405</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5514/#acomment-5527</link>
				<pubDate>Tue, 03 Feb 2026 10:35:10 +1300</pubDate>

									<content:encoded><![CDATA[<p>Looks like age and wear. No impact marks, just fatigue.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Damper blades are bent and out of alignment. Even with the actuator calling, airflow isn’t modulating evenly, which explains the uneven [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">285bd4d0f8402732bbeef2d6aaaa0c37</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5514/#acomment-5522</link>
				<pubDate>Tue, 03 Feb 2026 09:02:04 +1300</pubDate>

									<content:encoded><![CDATA[<p>Actuator’s doing its job, blades aren’t following.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Damper blades are bent and out of alignment. Even with the actuator calling, airflow isn’t modulating evenly, which explains the uneven [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">089ae80314295bf53b63786f4c5fd739</guid>
				<title>Elijah posted an update in the group HVAC Installation Best Practices: Damper blades are bent and out of alignment. Even with [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/5514/</link>
				<pubDate>Tue, 03 Feb 2026 07:15:58 +1300</pubDate>

									<content:encoded><![CDATA[<p>Damper blades are bent and out of alignment. Even with the actuator calling, airflow isn’t modulating evenly, which explains the uneven static and poor unit response.</p>
]]></content:encoded>
				
									<slash:comments>11</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">fe6937dfc9929b590ea00d339c8cea7c</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5368/#acomment-5394</link>
				<pubDate>Fri, 30 Jan 2026 07:15:22 +1300</pubDate>

									<content:encoded><![CDATA[<p>Wait… this is your first post?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/aidenj_official/" data-bb-hp-profile="26" rel="nofollow">Aiden</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> First post here, so thought I should finally introduce myself &#x1f604;					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">82ab85220171429e53cd540c9d76f697</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5119/#acomment-5158</link>
				<pubDate>Tue, 27 Jan 2026 15:40:27 +1300</pubDate>

									<content:encoded><![CDATA[<p>Cleaning was enough. Once the flow was back to normal, the system started behaving properly again.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Big problem on this heat exchanger almost blocked flow was very bad system not holding temp at all everything old space tight nothing wanted to [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8c5dcd9ba6c062d58f665d8b0bfe0a83</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5129/#acomment-5156</link>
				<pubDate>Tue, 27 Jan 2026 15:30:54 +1300</pubDate>

									<content:encoded><![CDATA[<p>From a customer’s perspective, this is the kind of fix they never see but benefit from immediately. From a technician’s side, it’s where experience really shows.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/carlos_d/" data-bb-hp-profile="37" rel="nofollow">Carlos</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Pressures were inconsistent during operation, which led to further inspection of the refrigerant line. A restriction was identified at [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a07d54b545e11ba50110b78bf63032b3</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5119/#acomment-5147</link>
				<pubDate>Tue, 27 Jan 2026 12:05:01 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yes, that’s exactly what it was. Flow through the heat exchanger was restricted, so the system kept running but never held temperature. Old valves and tight piping made isolating it take much longer than planned.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Big problem on this heat exchanger almost blocked flow was very bad system not holding temp at all everything old space tight nothing wanted to [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">701e4b3ad524d5573d5ea9b04faaf946</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5119/#acomment-5134</link>
				<pubDate>Tue, 27 Jan 2026 08:10:20 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yes one valve not closing fully took long time.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Big problem on this heat exchanger almost blocked flow was very bad system not holding temp at all everything old space tight nothing wanted to [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">547deb2bc5495e4dbc1ada4c28a3caba</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5119/#acomment-5126</link>
				<pubDate>Tue, 27 Jan 2026 05:55:44 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yes lot of dirt inside once open it was clear.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Big problem on this heat exchanger almost blocked flow was very bad system not holding temp at all everything old space tight nothing wanted to [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">1acea475278cd3ae601f4aed026302e0</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5119/#acomment-5123</link>
				<pubDate>Tue, 27 Jan 2026 04:21:30 +1300</pubDate>

									<content:encoded><![CDATA[<p>Main issue was flow heat exchanger almost blocked.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/elijah-thomos/" data-bb-hp-profile="79" rel="nofollow">Elijah</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Big problem on this heat exchanger almost blocked flow was very bad system not holding temp at all everything old space tight nothing wanted to [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">86cd625afbc65b74a6af807337be0121</guid>
				<title>Elijah posted an update in the group Troubleshooting &#038; Repairs: Big problem on this heat exchanger almost blocked flow [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/5119/</link>
				<pubDate>Tue, 27 Jan 2026 02:35:24 +1300</pubDate>

									<content:encoded><![CDATA[<p>Big problem on this heat exchanger almost blocked flow was very bad system not holding temp at all everything old space tight nothing wanted to move took way more time than planned just one of those days where you keep thinking it should be simple but it’s not.</p>
]]></content:encoded>
				
									<slash:comments>12</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">bb5a137b376d7b294ac6b3bc57c42471</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5078/#acomment-5099</link>
				<pubDate>Sun, 25 Jan 2026 10:30:46 +1300</pubDate>

									<content:encoded><![CDATA[<p>For me it’s usually the thermocouple, especially on older units.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/aidenj_official/" data-bb-hp-profile="26" rel="nofollow">Aiden</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> If a furnace pilot light keeps going out, what’s the first thing you usually check thermocouple, dirty pilot, or gas pressure?					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5c1898c9a5489535292267c3c10fde1b</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5072/#acomment-5093</link>
				<pubDate>Sun, 25 Jan 2026 07:31:12 +1300</pubDate>

									<content:encoded><![CDATA[<p>I’ve had days where I know for a fact I restocked them, and then when I’m on site and under pressure… nothing. Makes you feel like you’re losing it</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/matthewcollins_121/" data-bb-hp-profile="16" rel="nofollow">Matthew</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Had plenty of Schrader valve cores last week.
Needed one today gone.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5a8e924f002cd263ba212e1f4ffdad2c</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5033/#acomment-5036</link>
				<pubDate>Fri, 23 Jan 2026 23:34:20 +1300</pubDate>

									<content:encoded><![CDATA[<p>Clearly they’re watching a YouTube tutorial &#x1f602;</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jacobharris_official/" data-bb-hp-profile="89" rel="nofollow">Jacob</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Put the phones down, the unit’s watching &#x1f440;&#x1f602;??					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">cbc30759d29b904e29278bea7628cb02</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4907</link>
				<pubDate>Tue, 20 Jan 2026 16:47:57 +1300</pubDate>

									<content:encoded><![CDATA[<p>Customer probably watched you work for 3 hours thinking  this is expensive and then saw it fixed in 5 minutes.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">85849111c98f41671d3cb38c46340f98</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4690/#acomment-4720</link>
				<pubDate>Fri, 16 Jan 2026 11:43:20 +1300</pubDate>

									<content:encoded><![CDATA[<p>I’ve had houses sit at 45–50% and still feel dry because of short cycling. Numbers look fine, but the run time tells the real story.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/the_dylanparker/" data-bb-hp-profile="9" rel="nofollow">Dylan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Was checking voltage at the condenser today and had that moment where everything looked fine… but my gut said otherwise.
Didn’t chase it right [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">2cab6e8911815df92595d6cf0d10d55f</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4544/#acomment-4567</link>
				<pubDate>Tue, 13 Jan 2026 09:20:41 +1300</pubDate>

									<content:encoded><![CDATA[<p>Any history on the unit? Storms or power issues in the area lately?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jack-moore_15/" data-bb-hp-profile="83" rel="nofollow">Jack</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Check ground and incoming voltage before blaming the board. A lot of ‘bad boards’ aren’t bad at all.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">7241aa2e773aa733e623be60e8a0d45b</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4456/#acomment-4460</link>
				<pubDate>Sat, 10 Jan 2026 06:11:33 +1300</pubDate>

									<content:encoded><![CDATA[<p>I’ve seen this a lot where the system technically meets spec but behaves inconsistently because of how things were tied together over time.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/aidencooper/" data-bb-hp-profile="100" rel="nofollow">Aiden</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Opened the unit and found no single failed part, just inconsistent behavior caused by messy wiring and multiple small issues stacked [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bfe3e043ada860c4ff6a06448f4208c5</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4291/#acomment-4296</link>
				<pubDate>Sun, 04 Jan 2026 19:46:53 +1300</pubDate>

									<content:encoded><![CDATA[<p>Controller averaging or filtering too aggressive?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/owen_mitchell_27/" data-bb-hp-profile="104" rel="nofollow">Owen</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Mixed air temperature doesn’t match the math of OA and RA values.
Sensors are steady, economizer is responding, but the mixed reading [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">2417faca183c3e9df5c1795ca9e42376</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4248/#acomment-4253</link>
				<pubDate>Fri, 02 Jan 2026 17:58:45 +1300</pubDate>

									<content:encoded><![CDATA[<p>Wouldn’t surprise me if this started after a drain issue or a bad reheat cycle.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liam_brooks/" data-bb-hp-profile="53" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Internal fiberglass insulation inside the unit has degraded and detached. The insulation has sagged into the airflow path, collecting dust and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bc7eaddf9ec5ea24211119bbb01b215d</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4094/#acomment-4105</link>
				<pubDate>Mon, 29 Dec 2025 19:01:15 +1300</pubDate>

									<content:encoded><![CDATA[<p>Checked OK should be banned from service notes.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/salvatore_mancini_/" data-bb-hp-profile="42" rel="nofollow">Salvatore</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Walked into a job with a full service history attached… and still felt like I knew nothing.
Notes said checked, adjusted, monitor, but none of it [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0137025367be2155aa04e2ce060f695c</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4021/#acomment-4041</link>
				<pubDate>Fri, 26 Dec 2025 04:38:10 +1300</pubDate>

									<content:encoded><![CDATA[<p>Thanks for keeping this space active. Happy holidays.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> &#x1f384; Merry Christmas from HVAC Community Hub &#x1f384;

Wishing everyone here a peaceful holiday season and a well-earned break.
Thank [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">227c948b8a55f296bb03975726443ff9</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3843/#acomment-3858</link>
				<pubDate>Fri, 19 Dec 2025 11:17:30 +1300</pubDate>

									<content:encoded><![CDATA[<p>Seen this with dirty condenser coils that don’t look dirty at first glance.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas_foster/" data-bb-hp-profile="102" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Noticing condenser fan amps creeping up over a few weeks with no alarms and no visible mechanical issues.
Fans still stage and respond correctly, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">2f852952073503c8fb97d423ce77b40b</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3781/#acomment-3782</link>
				<pubDate>Wed, 17 Dec 2025 19:00:18 +1300</pubDate>

									<content:encoded><![CDATA[<p>If the system runs fine and occupants don’t feel it, it might be a monitoring artifact more than a real problem.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/grayson_ward/" data-bb-hp-profile="59" rel="nofollow">Grayson</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Been watching a drive that holds speed perfectly, airflow steady, no alarms &#8211; but torque keeps jumping around for no obvious [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f54e3e6524821e28dc08db6570b54781</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3438/#acomment-3445</link>
				<pubDate>Wed, 03 Dec 2025 19:51:36 +1300</pubDate>

									<content:encoded><![CDATA[<p>If the duct static is low with fan maxed, you’ve either got a leak, a blockage, or a bad sensor. Start with leakage.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/natcarter/" data-bb-hp-profile="17" rel="nofollow">Nathan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Showed up this morning and the supply fan is pegged at 100% again, and we’re STILL not hitting building static.
Feels like half the damn [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bea38bd451cd27082c04294d6d54182e</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3384/#acomment-3395</link>
				<pubDate>Tue, 02 Dec 2025 01:29:05 +1300</pubDate>

									<content:encoded><![CDATA[<p>Happens a lot on oversized fans. Too much inertia.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/andrea_santoro_22/" data-bb-hp-profile="30" rel="nofollow">Andrea</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Got a drive that behaves fine at full speed but trips on overvoltage the moment it starts slowing down.
No issues on ramp-up at [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8386a6c30170bca8d486cd19fd0d21d6</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3323/#acomment-3324</link>
				<pubDate>Wed, 26 Nov 2025 17:52:37 +1300</pubDate>

									<content:encoded><![CDATA[<p>Man… that thing’s been running on pure courage for at least 10 years.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jacobharris_official/" data-bb-hp-profile="89" rel="nofollow">Jacob</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Opened this VFD panel on a service call today &#8211; dust, loose wiring, and still running at 6000 like nothing’s wrong.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">374352b11202cc2393116649847df966</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3247/#acomment-3254</link>
				<pubDate>Mon, 24 Nov 2025 06:17:15 +1300</pubDate>

									<content:encoded><![CDATA[<p>Sweet! Now I can share my project pics too.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> &#x1f4e2; Hey everyone, good news!

A lot of you have been asking for this for a long time… and yes, we were quietly working on it in [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">b64ebc090ea8f86a8f2dbfa9d1089183</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3117/#acomment-3128</link>
				<pubDate>Mon, 17 Nov 2025 19:04:06 +1300</pubDate>

									<content:encoded><![CDATA[<p>Don’t touch condenser temp until you check flow. Low flow will surge a machine even at perfect temperatures.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a centrifugal chiller that keeps surging whenever the load drops and the condenser water temp gets too low.
IGVs and VFD look like they’re [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">7980d05f6768dce6d2301739869dcdc9</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2957/#acomment-2960</link>
				<pubDate>Wed, 12 Nov 2025 19:58:59 +1300</pubDate>

									<content:encoded><![CDATA[<p>Could be heat exchanger expanding and messing with the flame sensor ground. Happens on older units a lot.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/m-taylor/" data-bb-hp-profile="99" rel="nofollow">Mason</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> RTU heat stage acting up today.
First cycle runs smooth, then after a short call, it locks out for no clear reason.
Flame looks solid, pressure [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">d3859be61cec01bcd6b2c74fe4f951f7</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2883/#acomment-2896</link>
				<pubDate>Thu, 06 Nov 2025 17:03:24 +1300</pubDate>

									<content:encoded><![CDATA[<p>You can also reach out to Nordyne or ICP support; sometimes they still have old stock sitting in warehouses.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/the_dylanparker/" data-bb-hp-profile="9" rel="nofollow">Dylan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Ran into a Tempstar furnace today with a fried motor control module &#8211; and of course, it’s one of those DC boards that no longer exist anywhere in [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">21562695fe8ab81226b0be94ad126f57</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2637/#acomment-2642</link>
				<pubDate>Sat, 25 Oct 2025 14:07:07 +1300</pubDate>

									<content:encoded><![CDATA[<p>Please tell me when we can connect &#8211; I’ve been struggling with follow-ups.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/the-hvac-automation-blueprint/" data-bb-hp-group="6" rel="nofollow">The HVAC Automation Blueprint</a> Hey friends,

Automated email follow-ups are a game-changer for HVAC businesses &#8211; they help build trust, convert unresponsive [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f0cc67528673cfb37d19f4484c626d5a</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2582/#acomment-2587</link>
				<pubDate>Thu, 23 Oct 2025 13:57:39 +1300</pubDate>

									<content:encoded><![CDATA[<p>I guess my emails were partying in the spam folder without me &#x1f602;</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/the-hvac-automation-blueprint/" data-bb-hp-group="6" rel="nofollow">The HVAC Automation Blueprint</a> Hey friends,

Email marketing is powerful, but it only works if your messages actually reach your clients’ inboxes. Spam filters and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">01ce21e68685e16f7ac32307080742ab</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2448/#acomment-2451</link>
				<pubDate>Fri, 17 Oct 2025 14:08:31 +1300</pubDate>

									<content:encoded><![CDATA[<p>Could also be the blower itself -binding or dirty bearings can prevent proper ramping.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/theorousseau/" data-bb-hp-profile="91" rel="nofollow">Theo</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Been seeing some odd behavior with a variable speed drive on a rooftop unit. The motor won’t ramp properly, even though all the connections [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">efaabb8ce82563adff3bba0601192aaf</guid>
				<title>Elijah posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2283/#acomment-2290</link>
				<pubDate>Sun, 12 Oct 2025 21:24:17 +1300</pubDate>

									<content:encoded><![CDATA[<p>Check firmware updates too. Some older thermostats bug out after router updates.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/noahking_18/" data-bb-hp-profile="101" rel="nofollow">Noah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Ran into something weird today -a smart thermostat kept losing communication with the air handler, even though Wi-Fi and power were fine. Tried [&hellip;]					]]></content:encoded>
				
				