<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
		>

<channel>
	<title>HVAC Community Hub | Eric | Activity</title>
	<link>https://hvachub.co/members/ericcc82/activity/</link>
	<atom:link href="https://hvachub.co/members/ericcc82/activity/feed/" rel="self" type="application/rss+xml" />
	<description>Activity feed for Eric.</description>
	<lastBuildDate>Wed, 29 Apr 2026 12:59:07 +1200</lastBuildDate>
	<generator>https://buddypress.org/?v=2.18.0</generator>
	<language>en-US</language>
	<ttl>30</ttl>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>2</sy:updateFrequency>
		
								<item>
				<guid isPermaLink="false">f2e8ca1e3f6d295c4bbf81cf35ed87b0</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6753/#acomment-6761</link>
				<pubDate>Mon, 27 Apr 2026 21:17:25 +1200</pubDate>

									<content:encoded><![CDATA[<p>COD solves it real quick.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hwilliams/" data-bb-hp-profile="55" rel="nofollow">Harry</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Got a couple small commercial accounts that are good for the money, but every invoice turns into a wait.
Not chasing bad debt, they eventually pay… [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ddfc9615a9410f6b73e1c4b3a1b50e0d</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6733/#acomment-6738</link>
				<pubDate>Thu, 23 Apr 2026 05:24:19 +1200</pubDate>

									<content:encoded><![CDATA[<p>YouTube techs strike again.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/samuelscott13/" data-bb-hp-profile="86" rel="nofollow">Samuel</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Ever had a customer try to fix it themselves before calling you… and make it worse?					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">cca33930f717b8a03084ca4595d7319b</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6664/#acomment-6671</link>
				<pubDate>Thu, 16 Apr 2026 06:14:09 +1200</pubDate>

									<content:encoded><![CDATA[<p>That’s a bad contactor all day.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/rob_vitale64/" data-bb-hp-profile="45" rel="nofollow">Robert</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Swapped a contactor today that looked fine at a glance, but under load it was dropping voltage across the contacts. Getting about 240V in, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">27748c92e7c8592f7d095ec3545bd88e</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6583/#acomment-6584</link>
				<pubDate>Sat, 11 Apr 2026 23:19:06 +1200</pubDate>

									<content:encoded><![CDATA[<p>End of the day it’s usually something simple you assumed was fine.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/samuel-brown50/" data-bb-hp-profile="85" rel="nofollow">Samuel</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Callbacks are killing time over small misses lately. Anyone else dealing with this?					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0d52d22de688bd7586029e25a7fdd47c</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6460/#acomment-6464</link>
				<pubDate>Fri, 03 Apr 2026 17:47:59 +1300</pubDate>

									<content:encoded><![CDATA[<p>Agreed, past mergers often lead to reduced quality and service focus, making it tough for us in the repair community to rely on consistency.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachnelson/" data-bb-hp-profile="71" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Hey everyone, just heard the news about Mingledorff’s merging with The Home Depot. I’m curious what we think this means for us in the repair [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c4583164d6f3d3b4e3e0fb272a7eae45</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6442/#acomment-6443</link>
				<pubDate>Sat, 21 Mar 2026 09:46:33 +1300</pubDate>

									<content:encoded><![CDATA[<p> 1,840 and the manifold looked fine. That&#8217;s the whole argument for a micron gauge right there.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/mason-smith_18/" data-bb-hp-profile="90" rel="nofollow">Mason</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> 
Finally picked up a micron gauge this week. Been in the trade 9 years and have been judging vacuum on the manifold needle the whole time [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">60800bef7cedeec3b3f71fc86eebaba1</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6315/#acomment-6338</link>
				<pubDate>Tue, 17 Mar 2026 13:45:42 +1300</pubDate>

									<content:encoded><![CDATA[<p> I charge it, get it running, then do a full leak search while its operating at pressure. Better chance of finding it with the system running than with nitrogen anyway. If I find it I fix it same day. If I dont I document it and schedule a follow-up.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/andrea_santoro_22/" data-bb-hp-profile="30" rel="nofollow">Andrea</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> System is low on charge. No obvious leak. No oil staining anywhere on the lineset, no traces at the fittings, coil looks clean. Customer [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0be391e7dce7f3f5dbf1c963e71150f8</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6160/#acomment-6190</link>
				<pubDate>Thu, 19 Feb 2026 11:02:37 +1300</pubDate>

									<content:encoded><![CDATA[<p>Tell me you had to re-hang at least one section because it looked straight from the floor but crooked once you got up there.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> 30’ ceilings + scissor lift all day.
Trying to keep the trunk straight while dodging steel and sprinkler lines.
Whoever drew this on paper [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">dc577e8a18fd448540475c646d3d91c3</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6081/#acomment-6084</link>
				<pubDate>Sat, 14 Feb 2026 09:23:15 +1300</pubDate>

									<content:encoded><![CDATA[<p>We use HAP for most of our high-rise load calcs. Not perfect but it’s solid if you know how to use it properly.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/mason-smith_18/" data-bb-hp-profile="90" rel="nofollow">Mason</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Hello,					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a17330ba223176641f8a0d49d15f709d</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6013/#acomment-6053</link>
				<pubDate>Fri, 13 Feb 2026 17:50:37 +1300</pubDate>

									<content:encoded><![CDATA[<p>Appreciate that. EPA seems like the common answer here.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/andrea_santoro_22/" data-bb-hp-profile="30" rel="nofollow">Andrea</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> I’m looking at getting into HVAC and trying to figure out the best first step.
Trade school isn’t something I can commit to right now, so I’ve [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bf15aa1fdc027f018f25632a235bb0b9</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5928/#acomment-5951</link>
				<pubDate>Thu, 12 Feb 2026 10:25:00 +1300</pubDate>

									<content:encoded><![CDATA[<p>Let me guess… inspector shows up tomorrow and wants it moved 6 inches.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Spent more time planning the lift than the actual setting weights, rigging points, curb alignment, clearances. One bad pick and it’s an [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">90c65d0d2f097470c343751514c70faa</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5500/#acomment-5523</link>
				<pubDate>Tue, 03 Feb 2026 10:00:33 +1300</pubDate>

									<content:encoded><![CDATA[<p>Excel. Been using the same sheet for years. Ugly but it works.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/mason-smith_18/" data-bb-hp-profile="90" rel="nofollow">Mason</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Looking for recommendations on sales quoting software for unit replacements. Not trying to overcomplicate things just want something consistent, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ea4236d915c2655cc2f2f3f33266f300</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5015/#acomment-5030</link>
				<pubDate>Fri, 23 Jan 2026 17:51:22 +1300</pubDate>

									<content:encoded><![CDATA[<p>That’s true.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Didn’t even plan to post this, just snapped the picture and moved on. One of those moments where you see it, your brain goes huh… okay, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8fe109f9ca12d58dda9ff20c0478bd5a</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5015/#acomment-5026</link>
				<pubDate>Fri, 23 Jan 2026 11:47:36 +1300</pubDate>

									<content:encoded><![CDATA[<p>It’s not a good feeling.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Didn’t even plan to post this, just snapped the picture and moved on. One of those moments where you see it, your brain goes huh… okay, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5944e8d7f453341580067795b4461f49</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5015/#acomment-5022</link>
				<pubDate>Fri, 23 Jan 2026 09:36:00 +1300</pubDate>

									<content:encoded><![CDATA[<p>Not hope. Just timing.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Didn’t even plan to post this, just snapped the picture and moved on. One of those moments where you see it, your brain goes huh… okay, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">3a77d6d7aae7b287f748b0f228e21aaa</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5015/#acomment-5019</link>
				<pubDate>Fri, 23 Jan 2026 08:03:09 +1300</pubDate>

									<content:encoded><![CDATA[<p>That’s a fair way to put it.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Didn’t even plan to post this, just snapped the picture and moved on. One of those moments where you see it, your brain goes huh… okay, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4e182654842325b6cbe8959546886df7</guid>
				<title>Eric posted an update in the group HVAC Installation Best Practices: Didn’t even plan to post this, just snapped the picture [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/5015/</link>
				<pubDate>Fri, 23 Jan 2026 06:16:50 +1300</pubDate>

									<content:encoded><![CDATA[<p>Didn’t even plan to post this, just snapped the picture and moved on. One of those moments where you see it, your brain goes huh… okay, and you keep walking because you already know stopping to think about it will only make the day longer. It’s not wrong enough to fix immediately and not clean enough to feel good about, so it just sits there in&hellip;<span class="activity-read-more" id="activity-read-more-5015"><a href="https://hvachub.co/news-feed/p/5015/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>12</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">6e83dee9a92bfdc889d82c450e27ad83</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4908</link>
				<pubDate>Tue, 20 Jan 2026 16:56:56 +1300</pubDate>

									<content:encoded><![CDATA[<p>Explaining that part is always fun.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">37ac20bd583f717bdb3178f956a045ee</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4904</link>
				<pubDate>Tue, 20 Jan 2026 15:20:54 +1300</pubDate>

									<content:encoded><![CDATA[<p>True, but when you open something like this, discipline goes out the window.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8fb6f5f43051a3a45b8abb8c0eb3cfd3</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4901</link>
				<pubDate>Tue, 20 Jan 2026 13:23:00 +1300</pubDate>

									<content:encoded><![CDATA[<p>Everyone adds, nobody fixes.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">cd3697179453a33e3eb659406125fbc9</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4893</link>
				<pubDate>Tue, 20 Jan 2026 11:25:17 +1300</pubDate>

									<content:encoded><![CDATA[<p>Exactly. Replacement talk stopped real fast.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e92a6bc606b0b2a26ea79b98d42a20c2</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4885</link>
				<pubDate>Tue, 20 Jan 2026 09:21:39 +1300</pubDate>

									<content:encoded><![CDATA[<p>Best return on investment today.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">34bae31f951dcc1a7eecf837459a3023</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4879</link>
				<pubDate>Tue, 20 Jan 2026 07:10:32 +1300</pubDate>

									<content:encoded><![CDATA[<p>Once it failed during staging, we knew it wasn’t random anymore.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">9027df5ae753ff02b8e0276bba50a52c</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4868/#acomment-4872</link>
				<pubDate>Tue, 20 Jan 2026 05:39:13 +1300</pubDate>

									<content:encoded><![CDATA[<p>Word for word. Apparently it was dying since last year.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">dd58a2306e360e611af7cfd84aef200c</guid>
				<title>Eric posted an update in the group HVAC Installation Best Practices: Hey guys, something funny happened on site today. [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/4868/</link>
				<pubDate>Tue, 20 Jan 2026 03:50:37 +1300</pubDate>

									<content:encoded><![CDATA[<p>Hey guys, something funny happened on site today. The customer called saying the unit keeps shutting off randomly and cooling drops for some time, then comes back on its own. They couldn’t really explain much beyond that, so obviously we assumed it was something big &#8211; controls issue, board problem, staging logic, something buried deep in this&hellip;<span class="activity-read-more" id="activity-read-more-4868"><a href="https://hvachub.co/news-feed/p/4868/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>14</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">fce389d2ee161e472767c53b2c267124</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4598/#acomment-4651</link>
				<pubDate>Wed, 14 Jan 2026 11:30:40 +1300</pubDate>

									<content:encoded><![CDATA[<p>Depends. If the week was rough, the brain never shuts up.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Honest question because I’m curious
On your day off, are you actually resting
or still thinking about work you shouldn’t be thinking about?					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e01b55ae901dc81d2c45058a043f70bb</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4537/#acomment-4546</link>
				<pubDate>Tue, 13 Jan 2026 05:21:09 +1300</pubDate>

									<content:encoded><![CDATA[<p>Tried Instagram for 3 months. Got likes, zero calls. Felt like a waste of time honestly.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benjamin-harper/" data-bb-hp-profile="5" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Curious how many guys in here are actually using Facebook, Instagram, or anything else to bring in work.
Does it really help, or is it mostly [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0c2526195cb9a35674e9584da3efb907</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4410/#acomment-4420</link>
				<pubDate>Fri, 09 Jan 2026 08:10:35 +1300</pubDate>

									<content:encoded><![CDATA[<p>Owners don’t design ceilings.The contractor who signed off on that did.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/carlos_d/" data-bb-hp-profile="37" rel="nofollow">Carlos</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Today went for this job.From below the ceiling looked clean.Opened it up and… same story again.
Multiple units, tight space, no access.
And [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4a4e64514612b022798d24a54c2edde0</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4309/#acomment-4322</link>
				<pubDate>Tue, 06 Jan 2026 18:30:13 +1300</pubDate>

									<content:encoded><![CDATA[<p>This is every nothing’s wrong call ever.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/julien_bernard_48/" data-bb-hp-profile="60" rel="nofollow">Julien</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Everything checks out on paper, but the space still doesn’t feel right.
Air’s moving &#8211; just not where it’s supposed to anymore.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ea52123e657c9337622815443fa42602</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4196/#acomment-4199</link>
				<pubDate>Thu, 01 Jan 2026 19:36:12 +1300</pubDate>

									<content:encoded><![CDATA[<p>Designed by someone who’s never been on a roof at noon.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ryanbennett/" data-bb-hp-profile="20" rel="nofollow">Ryan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Access looks fine in drawings.
Up here, it’s a different job altogether.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">30b8d328b022e1a45219f42ed81880e2</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4133/#acomment-4134</link>
				<pubDate>Tue, 30 Dec 2025 14:27:30 +1300</pubDate>

									<content:encoded><![CDATA[<p>This is honestly where so many jobs fall apart. No clear ownership, no clear authority, and everyone assumes someone else is responsible. You can fix equipment all day but that part never gets addressed.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/mason-smith_18/" data-bb-hp-profile="90" rel="nofollow">Mason</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Didn’t even touch the unit today.
Spent 40 minutes just figuring out who actually controls it &#8211; tenant says one thing, building manager says [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">46d60630779ba57e82fbb9404adfc01d</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3873/#acomment-3880</link>
				<pubDate>Fri, 19 Dec 2025 11:17:48 +1300</pubDate>

									<content:encoded><![CDATA[<p>Nothing worse than getting a lead 3 hours late and being told “they already booked.”</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/agustinlopez01/" data-bb-hp-profile="25" rel="nofollow">Agustin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-lead-generation-mastery/" data-bb-hp-group="5" rel="nofollow">HVAC Lead Generation Mastery</a> One thing I keep noticing across high-performing HVAC businesses: lead volume isn’t the bottleneck anymore -lead timing is.
The same campaign [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ac20fc2dfa09b94fe3a0d4574c8b26d6</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3624/#acomment-3625</link>
				<pubDate>Mon, 15 Dec 2025 09:44:54 +1300</pubDate>

									<content:encoded><![CDATA[<p>Airflow might be too high. Coil can’t pull moisture if the air is flying past it.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Cooling’s doing its job on temperature, but RH keeps creeping up anyway.
Feels like dehumidification is getting undercut somewhere &#8211; airflow, coil, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">491212e8325206b5be37558f4146db2f</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3399/#acomment-3400</link>
				<pubDate>Tue, 02 Dec 2025 01:29:08 +1300</pubDate>

									<content:encoded><![CDATA[<p>check the actuator timing. if one damper is lagging a few seconds it’ll swing like crazy.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/rob_vitale64/" data-bb-hp-profile="45" rel="nofollow">Robert</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> noticed the mix plenum temp jumping all over the place today… like 8-10° swings even though OA + RA temps aren’t moving.
dampers [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f73971cfd1a2b2752faf7d60da78c634</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3331/#acomment-3332</link>
				<pubDate>Thu, 27 Nov 2025 19:48:12 +1300</pubDate>

									<content:encoded><![CDATA[<p>If it’s slow drift instead of instant jumps, it’s usually a failing sensor body.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/camerongray/" data-bb-hp-profile="36" rel="nofollow">Cameron</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Got a strange one today: several thermistors are drifting 5–7°F again right after calibration.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">b0af50542544940d60e41b64c956e602</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3117/#acomment-3129</link>
				<pubDate>Mon, 17 Nov 2025 19:04:07 +1300</pubDate>

									<content:encoded><![CDATA[<p>Good point &#8211; I’ll confirm GPM before making changes.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a centrifugal chiller that keeps surging whenever the load drops and the condenser water temp gets too low.
IGVs and VFD look like they’re [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a1a36d98f666e5b2c7dd2e6928dd6065</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3117/#acomment-3127</link>
				<pubDate>Mon, 17 Nov 2025 19:04:05 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yeah, a small temp increase might calm it down.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a centrifugal chiller that keeps surging whenever the load drops and the condenser water temp gets too low.
IGVs and VFD look like they’re [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">af50b9c853c132d08f971588cd1dbf79</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3117/#acomment-3125</link>
				<pubDate>Mon, 17 Nov 2025 19:04:04 +1300</pubDate>

									<content:encoded><![CDATA[<p>Haven’t checked it yet &#8211; I’ll add that to the list.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a centrifugal chiller that keeps surging whenever the load drops and the condenser water temp gets too low.
IGVs and VFD look like they’re [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">dd6625c07c59933a031b2e2d243c010e</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3117/#acomment-3123</link>
				<pubDate>Mon, 17 Nov 2025 19:04:02 +1300</pubDate>

									<content:encoded><![CDATA[<p>&#x1f602; Exactly. Sounds like it’s coughing every few minutes.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a centrifugal chiller that keeps surging whenever the load drops and the condenser water temp gets too low.
IGVs and VFD look like they’re [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c6ed134efce7aea4ffd6daed7a1b8416</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3117/#acomment-3119</link>
				<pubDate>Mon, 17 Nov 2025 19:03:58 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yeah, that reset curve might be too aggressive. I’ll trend it tomorrow.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a centrifugal chiller that keeps surging whenever the load drops and the condenser water temp gets too low.
IGVs and VFD look like they’re [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ed83b1d040054afc6810614695b0f62b</guid>
				<title>Eric posted an update in the group HVAC Installation Best Practices: Got a centrifugal chiller that keeps surging whenever [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/3117/</link>
				<pubDate>Mon, 17 Nov 2025 19:03:57 +1300</pubDate>

									<content:encoded><![CDATA[<p>Got a centrifugal chiller that keeps surging whenever the load drops and the condenser water temp gets too low.<br />
IGVs and VFD look like they’re doing their job, but the machine still slips into surge every few minutes at part load.<br />
Trying to figure out if this is a control sequence issue or something in the condenser side causing unstable conditions.</p>
]]></content:encoded>
				
									<slash:comments>12</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">20be0d6a89bd32fe91d359b8a8c6f445</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3008/#acomment-3011</link>
				<pubDate>Fri, 14 Nov 2025 19:20:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>Seen this plenty &#8211; the VFD’s comm card gets noisy when the motor load shifts. Try isolating the shield at one end only.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/andrea_santoro_22/" data-bb-hp-profile="30" rel="nofollow">Andrea</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> The AHU’s fan VFD keeps dropping off the BAS network for a couple seconds at a time, then snaps back like nothing happened.
Cabling and grounding look [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c46278806adb82c380438d4fc3dfd9dc</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2939/#acomment-2951</link>
				<pubDate>Wed, 12 Nov 2025 19:58:52 +1300</pubDate>

									<content:encoded><![CDATA[<p>Exactly. I’ve seen that &#8211; one extra load and the transformer can’t handle startup draw.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a 24V control circuit that drops to around 18–19 volts as soon as multiple relays kick in.
No direct shorts found, wiring looks clean, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">98a7ebf4a0e7b97c5c0a1f1dce134cb4</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2939/#acomment-2949</link>
				<pubDate>Wed, 12 Nov 2025 19:58:51 +1300</pubDate>

									<content:encoded><![CDATA[<p>Interesting idea &#8211; I’ll put the meter in min/max mode first, maybe even throw the scope on if it looks unstable.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a 24V control circuit that drops to around 18–19 volts as soon as multiple relays kick in.
No direct shorts found, wiring looks clean, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c3827962ad1954bbc47901cde8e618ea</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2939/#acomment-2947</link>
				<pubDate>Wed, 12 Nov 2025 19:58:48 +1300</pubDate>

									<content:encoded><![CDATA[<p>That’s true. This system has a few parallel loads &#8211; I’ll check if they’re all daisy-chained on one return.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a 24V control circuit that drops to around 18–19 volts as soon as multiple relays kick in.
No direct shorts found, wiring looks clean, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">fc985a9fac462ea3a56b2d9908d0b7dc</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2939/#acomment-2945</link>
				<pubDate>Wed, 12 Nov 2025 19:58:47 +1300</pubDate>

									<content:encoded><![CDATA[<p>Nice catch. I’ll ohm out each relay coil to see if one’s dragging the voltage.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a 24V control circuit that drops to around 18–19 volts as soon as multiple relays kick in.
No direct shorts found, wiring looks clean, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f5296314aecdc09579ac29662afcbd7b</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2939/#acomment-2943</link>
				<pubDate>Wed, 12 Nov 2025 19:58:45 +1300</pubDate>

									<content:encoded><![CDATA[<p>Good one &#8211; I’ll go through the junction box again. Could be a weak connection somewhere.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a 24V control circuit that drops to around 18–19 volts as soon as multiple relays kick in.
No direct shorts found, wiring looks clean, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">56a43e2c95eff6cea0c6c358b62e1d6f</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2939/#acomment-2941</link>
				<pubDate>Wed, 12 Nov 2025 19:58:42 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yeah, that’s what it feels like. Gonna throw a load tester on it tomorrow to confirm.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Got a 24V control circuit that drops to around 18–19 volts as soon as multiple relays kick in.
No direct shorts found, wiring looks clean, and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ae245d976790f2b1f6f7ba12879336f8</guid>
				<title>Eric posted an update in the group HVAC Installation Best Practices: Got a 24V control circuit that drops to around 18–19 volts [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/2939/</link>
				<pubDate>Wed, 12 Nov 2025 19:58:41 +1300</pubDate>

									<content:encoded><![CDATA[<p>Got a 24V control circuit that drops to around 18–19 volts as soon as multiple relays kick in.<br />
No direct shorts found, wiring looks clean, and the transformer checks fine on idle.<br />
Feels like either a load imbalance or a weak transformer that can’t hold under demand &#8211; gonna dig deeper tomorrow.</p>
]]></content:encoded>
				
									<slash:comments>12</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">c3243e3c9d85db045d3bed6423f3e7d4</guid>
				<title>Eric posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2837/#acomment-2849</link>
				<pubDate>Tue, 04 Nov 2025 21:16:49 +1300</pubDate>

									<content:encoded><![CDATA[<p>Good catch. I’ll recheck sensor placement and tubing, that could easily explain the spikes.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ericcc82/" data-bb-hp-profile="10" rel="nofollow">Eric</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Newly commissioned duct system keeps tripping high static pressure alarms at full load &#8211; fans and dampers check out fine.
Looks like a sizing or [&hellip;]					]]></content:encoded>
				
				