<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
		>

<channel>
	<title>HVAC Community Hub | Liam | Activity</title>
	<link>https://hvachub.co/members/liambrooks_biz/activity/</link>
	<atom:link href="https://hvachub.co/members/liambrooks_biz/activity/feed/" rel="self" type="application/rss+xml" />
	<description>Activity feed for Liam.</description>
	<lastBuildDate>Wed, 29 Apr 2026 12:59:07 +1200</lastBuildDate>
	<generator>https://buddypress.org/?v=2.18.0</generator>
	<language>en-US</language>
	<ttl>30</ttl>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>2</sy:updateFrequency>
		
								<item>
				<guid isPermaLink="false">6ccd0337f73f8608d459095dfc1b023d</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6393/#acomment-6413</link>
				<pubDate>Fri, 20 Mar 2026 12:50:09 +1300</pubDate>

									<content:encoded><![CDATA[<p>Check the compressor carefully before you just swap the contactor and call it done. Compressor running continuously through cold ambient with no load cycling can cause liquid slugging and bearing wear.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/milescollins_business/" data-bb-hp-profile="67" rel="nofollow">Miles</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Spring startup call this week. Customer mentioned the system had been running a lot lately but didn&#8217;t think much of it.
Opened the panel [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">df7f60ad9db45423339e8987ffa36aba</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6405/#acomment-6411</link>
				<pubDate>Fri, 20 Mar 2026 10:48:33 +1300</pubDate>

									<content:encoded><![CDATA[<p>Done thousands of repairs. Purged on new installs, used judgment on repairs. Never had a callback I could trace to oxidation from a short braze on an existing system.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas_reed/" data-bb-hp-profile="15" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Nitrogen purge when brazing. Every time. No exceptions.
That&#8217;s what we&#8217;re taught and honestly that&#8217;s what I believe. But I&#8217;ve had this argument [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">101c901624c95f3ac57133e57f776fe5</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6244/#acomment-6251</link>
				<pubDate>Wed, 11 Mar 2026 02:20:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>Age matters for sure. Hard to justify sinking money into something near the end of its life.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lukeperez/" data-bb-hp-profile="84" rel="nofollow">Luke</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> How are you guys handling leaking evaporator coils these days? Are you still repairing them when it makes sense, or just going straight [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ea47c5196eb80829bb136cab5ef5fb76</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6155/#acomment-6193</link>
				<pubDate>Thu, 19 Feb 2026 11:21:06 +1300</pubDate>

									<content:encoded><![CDATA[<p>Facts. Anyone can post shiny installs. It’s how you handle problems that sticks.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/graysonwest_official/" data-bb-hp-profile="103" rel="nofollow">Grayson</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Most customers won’t remember the exact number on the invoice a year from now.
But they’ll remember if you showed up when you said you would, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">2241239b77b21ccf8c9f15bc6a94cfb8</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5868/#acomment-5923</link>
				<pubDate>Wed, 11 Feb 2026 18:48:40 +1300</pubDate>

									<content:encoded><![CDATA[<p>Fuel isn’t free and neither is rolling a truck in a storm. They paid for someone to show up, and that’s exactly what happened.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/iamloganrabinson/" data-bb-hp-profile="69" rel="nofollow">Logan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Rolled a truck in a snowstorm for an emergency call. Fee paid upfront. Homeowner fixed it themselves by the time we got there and wanted a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0dd279d5cdf5271a9bc088647b5d783a</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5820/#acomment-5822</link>
				<pubDate>Tue, 10 Feb 2026 09:25:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>That smell stays in your truck all day too.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/aidencooper/" data-bb-hp-profile="100" rel="nofollow">Aiden</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> This motor’s been making noise for a while.
Guess today was the day it finally quit.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bbc7919696097b706faa9ef52a87ad86</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5598/#acomment-5638</link>
				<pubDate>Thu, 05 Feb 2026 12:25:32 +1300</pubDate>

									<content:encoded><![CDATA[<p>Builders will shop your number even if they never plan to use you. Happens all the time.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ethanlewis_12/" data-bb-hp-profile="68" rel="nofollow">Ethan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Trying to tighten up how I’m pricing new residential builds. I’ll go deep into plans, take my time, and still end up missing jobs or finding out [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4d6966bc74d30fd1927cc6886df20133</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5264/#acomment-5266</link>
				<pubDate>Thu, 29 Jan 2026 04:30:41 +1300</pubDate>

									<content:encoded><![CDATA[<p>We went cheap at first and learned the hard way. Coverage matters way more than monthly cost.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/adam_29/" data-bb-hp-profile="4" rel="nofollow">Adam</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Hey everyone &#x1f44b;					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">3593675c09d39c0fe39f6c3ec1fdca33</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4862/#acomment-4867</link>
				<pubDate>Tue, 20 Jan 2026 03:49:16 +1300</pubDate>

									<content:encoded><![CDATA[<p>No sleeve, no proper penetration seal. That’s a problem.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas_reed/" data-bb-hp-profile="15" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Started as a temporary fix.
Somehow it became part of the system.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">d79de872a175b37583d105b7ea11d306</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4663/#acomment-4664</link>
				<pubDate>Wed, 14 Jan 2026 21:07:53 +1300</pubDate>

									<content:encoded><![CDATA[<p>Vacuum time alone doesn’t mean much if you’re not watching decay. Long pull could be leaks, moisture, or just bad hoses.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hwilliams/" data-bb-hp-profile="55" rel="nofollow">Harry</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Pulled up thinking this was going to be a quick in-and-out.
Hooked up, started pulling down, and that’s when you already know how the rest of the call [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">621717d5af7d6260a47220186283f2c6</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4259/#acomment-4265</link>
				<pubDate>Fri, 02 Jan 2026 17:58:57 +1300</pubDate>

									<content:encoded><![CDATA[<p>What kind of coffee though? Black or milk?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/edwardmitchell_07/" data-bb-hp-profile="80" rel="nofollow">Edward</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> It’s freezing outside today.
One of those mornings where the coffee matters more than usual.Pretty sure half the day is just trying to stay warm and awake.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e4bf9c38ef23489fe1deaf02d2df7e93</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3843/#acomment-3856</link>
				<pubDate>Fri, 19 Dec 2025 11:17:28 +1300</pubDate>

									<content:encoded><![CDATA[<p>If it’s on VFDs, make sure the feedback is actually real and not estimated.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas_foster/" data-bb-hp-profile="102" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Noticing condenser fan amps creeping up over a few weeks with no alarms and no visible mechanical issues.
Fans still stage and respond correctly, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">946e362c676e7682b496b6afadd7c8c7</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3781/#acomment-3790</link>
				<pubDate>Wed, 17 Dec 2025 19:00:21 +1300</pubDate>

									<content:encoded><![CDATA[<p>If speed and amps are flat but torque jumps, I’d look at the torque calc itself. Some drives get noisy with feedback.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/grayson_ward/" data-bb-hp-profile="59" rel="nofollow">Grayson</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Been watching a drive that holds speed perfectly, airflow steady, no alarms &#8211; but torque keeps jumping around for no obvious [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4e1e5394967ce38478a4e952f182399d</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3484/#acomment-3492</link>
				<pubDate>Tue, 09 Dec 2025 19:13:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>right? the building only acts up when there’s no one around to yell at it.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Mixed air temp decides to jump 6–8°F every time night mode kicks in, even though OA and RA aren’t moving an inch.
Pretty sure the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">eea67bc76553db5338f4dbbc91180042</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3484/#acomment-3490</link>
				<pubDate>Tue, 09 Dec 2025 19:13:18 +1300</pubDate>

									<content:encoded><![CDATA[<p>true- half the sensors in this place are in questionable spots.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Mixed air temp decides to jump 6–8°F every time night mode kicks in, even though OA and RA aren’t moving an inch.
Pretty sure the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bbe38915e8166c17abbb21502b5f61b2</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3484/#acomment-3488</link>
				<pubDate>Tue, 09 Dec 2025 19:13:16 +1300</pubDate>

									<content:encoded><![CDATA[<p>yeah feels like it’s hanging onto daytime settings just out of spite.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Mixed air temp decides to jump 6–8°F every time night mode kicks in, even though OA and RA aren’t moving an inch.
Pretty sure the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f90e324ff742a5b70d3e2ca1038478df</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3484/#acomment-3486</link>
				<pubDate>Tue, 09 Dec 2025 19:13:14 +1300</pubDate>

									<content:encoded><![CDATA[<p>completely unmonitored chaos after 6pm apparently.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Mixed air temp decides to jump 6–8°F every time night mode kicks in, even though OA and RA aren’t moving an inch.
Pretty sure the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">674592ec6699be4f398836d7bfd15177</guid>
				<title>Liam posted an update in the group HVAC Installation Best Practices: Mixed air temp decides to jump 6–8°F every time night [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/3484/</link>
				<pubDate>Tue, 09 Dec 2025 19:13:13 +1300</pubDate>

									<content:encoded><![CDATA[<p>Mixed air temp decides to jump 6–8°F every time night mode kicks in, even though OA and RA aren’t moving an inch.<br />
Pretty sure the economizer’s out here doing whatever it wants after hours.</p>
]]></content:encoded>
				
									<slash:comments>8</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">f14915f1cae6f5c1e9c5f2bbb332ad74</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3233/#acomment-3241</link>
				<pubDate>Thu, 20 Nov 2025 19:17:25 +1300</pubDate>

									<content:encoded><![CDATA[<p>I just resend it manually when this happens. Quick fix but annoying.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-crm-playbook-from-lead-capture-to-customer-loyalty/" data-bb-hp-group="12" rel="nofollow">HVAC CRM Playbook: From Lead Capture To Customer Loyalty</a> Anyone else sending estimates through the CRM that show “sent,” but customers keep saying they never received [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">791b52628ac0074d3b0363947240376b</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3096/#acomment-3109</link>
				<pubDate>Mon, 17 Nov 2025 19:03:51 +1300</pubDate>

									<content:encoded><![CDATA[<p>Thanks for doing this. It really helps.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/noahgrant/" data-bb-hp-profile="18" rel="nofollow">Noah</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-email-pipeline-builder-nurture-leads-follow-up-close-more-deals/" data-bb-hp-group="8" rel="nofollow">HVAC Email Pipeline Builder |Nurture Leads. Follow Up. Close More Deals</a> I’ve been noticing that a lot of members are working hard on improving their follow-ups, but the email [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a064b5e9fe6f50f34c9ff673bfcac6f6</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2560/#acomment-2568</link>
				<pubDate>Wed, 22 Oct 2025 13:56:24 +1300</pubDate>

									<content:encoded><![CDATA[<p>Good idea, I’ll log the load conditions over a few hours.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Noticed the evaporator coil icing up on a commercial AC. Airflow looks fine, refrigerant charge seems correct, but the coil keeps freezing [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">aac9442c72957c200c11ec6203b0d5b2</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2560/#acomment-2566</link>
				<pubDate>Wed, 22 Oct 2025 13:56:23 +1300</pubDate>

									<content:encoded><![CDATA[<p>&#x1f602; Wouldn’t that make service calls more fun!</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Noticed the evaporator coil icing up on a commercial AC. Airflow looks fine, refrigerant charge seems correct, but the coil keeps freezing [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e04949997f4d6cdc1838e665d5fb2e8f</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2560/#acomment-2564</link>
				<pubDate>Wed, 22 Oct 2025 13:56:21 +1300</pubDate>

									<content:encoded><![CDATA[<p>Haha, if only HVAC components had moods!</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Noticed the evaporator coil icing up on a commercial AC. Airflow looks fine, refrigerant charge seems correct, but the coil keeps freezing [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">3635b1b494fcb6748447d1d989c3f8bb</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2560/#acomment-2562</link>
				<pubDate>Wed, 22 Oct 2025 13:56:20 +1300</pubDate>

									<content:encoded><![CDATA[<p>True, I’ll double-check the airflow even though it looks fine.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Noticed the evaporator coil icing up on a commercial AC. Airflow looks fine, refrigerant charge seems correct, but the coil keeps freezing [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f687acf6207be4eaada7ac86885376ae</guid>
				<title>Liam posted an update in the group HVAC Tools &#038; Equipment: Noticed the evaporator coil icing up on a commercial [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/2560/</link>
				<pubDate>Wed, 22 Oct 2025 13:56:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>Noticed the evaporator coil icing up on a commercial AC. Airflow looks fine, refrigerant charge seems correct, but the coil keeps freezing intermittently. Could this be a TXV issue, low load, or hidden restriction?</p>
]]></content:encoded>
				
									<slash:comments>7</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">b147169cc7e59fbc4e11b8a7a0db03e1</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2492/#acomment-2503</link>
				<pubDate>Sun, 19 Oct 2025 14:02:10 +1300</pubDate>

									<content:encoded><![CDATA[<p>Is the condenser in direct sun? Ambient temps can skew discharge pressures too.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/connorh/" data-bb-hp-profile="8" rel="nofollow">Connor</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Condenser fan motor is spinning fine, but discharge pressures are high and system isn’t hitting setpoint. No obvious airflow restrictions &#8211; could this [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">3c68747d9dbc85bcf30edaf5573d89eb</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2460/#acomment-2471</link>
				<pubDate>Sat, 18 Oct 2025 14:03:02 +1300</pubDate>

									<content:encoded><![CDATA[<p>Tracking replies also helps &#8211; it’s real feedback from potential clients.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-email-pipeline-builder-nurture-leads-follow-up-close-more-deals/" data-bb-hp-group="8" rel="nofollow">HVAC Email Pipeline Builder |Nurture Leads. Follow Up. Close More Deals</a> Email marketing is only as good as the data you pay attention to. Tracking the right [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c0f8ec2dfb311b7c12dd91c8a9f062c3</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2018/#acomment-2035</link>
				<pubDate>Thu, 02 Oct 2025 17:29:39 +1300</pubDate>

									<content:encoded><![CDATA[<p>How often do you guys automate follow-ups? After 2 days, 1 week, or more?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-crm-playbook-from-lead-capture-to-customer-loyalty/" data-bb-hp-group="12" rel="nofollow">HVAC CRM Playbook: From Lead Capture To Customer Loyalty</a> Hey guys,

Let’s talk about quotes &#8211; one of the most important steps in closing HVAC jobs. A lot of [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">d160a9257e07e64763d8a5f380bbd4d5</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1858/#acomment-1871</link>
				<pubDate>Tue, 23 Sep 2025 18:35:41 +1200</pubDate>

									<content:encoded><![CDATA[<p>Advanced systems aren’t the issue; it’s the basics that trip them up.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas_foster/" data-bb-hp-profile="102" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Been feeling the pinch lately when it comes to hiring skilled techs, especially in VRF and automation systems. It’s like every new hire is [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a47b643b4ba1d87890da676c825b4e37</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1747/#acomment-1750</link>
				<pubDate>Tue, 16 Sep 2025 10:55:53 +1200</pubDate>

									<content:encoded><![CDATA[<p>Check the filter too; a clogged one can mess up airflow and humidity control.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/austinmitchell_89/" data-bb-hp-profile="32" rel="nofollow">Austin</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Just wrapped up a full system service at a commercial spot, but the client&#8217;s still not satisfied. They keep complaining about dry air and [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8f831f26bea0511b3e14bf9639b98f0b</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1693/#acomment-1714</link>
				<pubDate>Sun, 07 Sep 2025 13:54:07 +1200</pubDate>

									<content:encoded><![CDATA[<p>We don’t have a CRM yet. Can automation still work?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benjamin-harper/" data-bb-hp-profile="5" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-email-pipeline-builder-nurture-leads-follow-up-close-more-deals/" data-bb-hp-group="8" rel="nofollow">HVAC Email Pipeline Builder |Nurture Leads. Follow Up. Close More Deals</a> One thing I keep noticing in our community: many HVAC contractors are still treating email like [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c05eb83c27a4b38fdeeb7632c03a0f9f</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1678/#acomment-1691</link>
				<pubDate>Sun, 07 Sep 2025 13:53:52 +1200</pubDate>

									<content:encoded><![CDATA[<p>Clients never want to spend on this, they think it’s just upselling.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/owen-green/" data-bb-hp-profile="51" rel="nofollow">Owen</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> I feel like a lot of teams don’t really talk about recommissioning. Most people think once the system is installed and handed over, that’s it. But over [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a5a17f094cb81458041246a1549bb928</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1204/#acomment-1205</link>
				<pubDate>Mon, 11 Aug 2025 14:23:28 +1200</pubDate>

									<content:encoded><![CDATA[<p>Love the shared folder idea. We did BIM clash detection last month-saved us having to rip out freshly installed ducts under a beam!</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/calebdavis_pro/" data-bb-hp-profile="34" rel="nofollow">Caleb</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Wrapped up a multi-trade site install this week-hosted a kickoff with HVAC, plumbing, electrical, and fire protection. We used a shared [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f6bcf1d94fab833f5889d93c3ee67dc8</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1051/#acomment-1059</link>
				<pubDate>Tue, 22 Jul 2025 18:43:21 +1200</pubDate>

									<content:encoded><![CDATA[<p>That layout works from US to Middle East &#8211; just adjust pad height or add wind guard as needed.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hunterreed_biz/" data-bb-hp-profile="43" rel="nofollow">Hunter</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Just finished a rooftop install with proper clearances: 36 from wall, 72 between units for the larger 15‑ton split condensers, and at least [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">9d2aaaa2a357388228443d57f1c6e63f</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/997/#acomment-1005</link>
				<pubDate>Sat, 19 Jul 2025 09:17:20 +1200</pubDate>

									<content:encoded><![CDATA[<p>Use performance KPIs (milestones met, punch-rate) for tracking subs.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/agustinlopez01/" data-bb-hp-profile="25" rel="nofollow">Agustin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> We had a major job delayed 3 weeks because the duct subcontractor fell behind-ended up implementing weekly progress syncs and a shared [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">2bab0067bca6b9b99c9b2552e6f2911a</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/941/#acomment-955</link>
				<pubDate>Thu, 17 Jul 2025 12:17:55 +1200</pubDate>

									<content:encoded><![CDATA[<p>Absolutely—most refrigerant add-ons on these systems were unnecessary.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">fd72d96c90b49149b35327232f59d601</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/941/#acomment-953</link>
				<pubDate>Thu, 17 Jul 2025 12:17:54 +1200</pubDate>

									<content:encoded><![CDATA[<p>True—the psic toolbox showed where airflow was getting strangled.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0b1537078d36f5c7acda270d4af285aa</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/941/#acomment-951</link>
				<pubDate>Thu, 17 Jul 2025 12:17:54 +1200</pubDate>

									<content:encoded><![CDATA[<p>Great point—climate adjustments make all the difference in design.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c22abf8d3dced91173933fd30e3ccd38</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/941/#acomment-949</link>
				<pubDate>Thu, 17 Jul 2025 12:17:54 +1200</pubDate>

									<content:encoded><![CDATA[<p>That range hits the sweet spot—efficiency and comfort both.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e240d5249b5a8303aa375e40695c0806</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/941/#acomment-947</link>
				<pubDate>Thu, 17 Jul 2025 12:17:53 +1200</pubDate>

									<content:encoded><![CDATA[<p>Good call—ECM tuning saved time and balanced zones instantly.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f8b4cc96923f7e11b36041899763952e</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/941/#acomment-945</link>
				<pubDate>Thu, 17 Jul 2025 12:17:53 +1200</pubDate>

									<content:encoded><![CDATA[<p>Yes ambient conditions make airflow critical in those climates.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">4957c737da625147d3956484537b252c</guid>
				<title>Liam posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/941/#acomment-943</link>
				<pubDate>Thu, 17 Jul 2025 12:17:53 +1200</pubDate>

									<content:encoded><![CDATA[<p>Exactly—we found a clogged filter and minor duct leaks causing our worst efficiency drop.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liambrooks_biz/" data-bb-hp-profile="98" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e4dfd82fcb4f22882b79bb0642a33d92</guid>
				<title>Liam posted an update in the group HVAC Contractors &#038; Subcontractors: Most commercial systems run well below spec—our audit [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/941/</link>
				<pubDate>Thu, 17 Jul 2025 12:17:53 +1200</pubDate>

									<content:encoded><![CDATA[<p>Most commercial systems run well below spec—our audit showed 340 CFM/ton vs. the ideal 400 CFM/ton—and over 60% of systems suffer low airflow. Much of the loss is due to duct leaks and filter issues.</p>
]]></content:encoded>
				