<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
		>

<channel>
	<title>HVAC Community Hub | Zachary | Activity</title>
	<link>https://hvachub.co/members/zachary1/activity/</link>
	<atom:link href="https://hvachub.co/members/zachary1/activity/feed/" rel="self" type="application/rss+xml" />
	<description>Activity feed for Zachary.</description>
	<lastBuildDate>Wed, 12 Aug 2026 00:23:45 +1200</lastBuildDate>
	<generator>https://buddypress.org/?v=3.3.0</generator>
	<language>en-US</language>
	<ttl>30</ttl>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>2</sy:updateFrequency>
		
								<item>
				<guid isPermaLink="false">256a4239dac2fbb07e380b7a9e403fc1</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/8451/#acomment-8499</link>
				<pubDate>Sun, 09 Aug 2026 23:54:53 +1200</pubDate>

									<content:encoded><![CDATA[<p>Who installed this system and didn&#8217;t put a float switch on the emergency pan? That&#8217;s code in most states now.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/brandonfoster32/" data-bb-hp-profile="6" rel="nofollow">Brandon</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Went outside to check the condensate drain and found this &#x1f644;. New homeowner, bought the house last year, system has never been serviced. The drain [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">915c4af7b2a590f118a443bdf64d1bfa</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/8305/#acomment-8340</link>
				<pubDate>Sun, 02 Aug 2026 02:41:30 +1200</pubDate>

									<content:encoded><![CDATA[<p>Stay hydrated brother.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jackcooper/" data-bb-hp-profile="40" rel="nofollow">Jack</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Maintenance contract call on a rooftop today. Carrier package unit installed last year, customer said it&#8217;s been running fine but wanted [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">1b990d0192f059908c5094a8306a098c</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/8335/#acomment-8338</link>
				<pubDate>Sun, 02 Aug 2026 01:31:04 +1200</pubDate>

									<content:encoded><![CDATA[<p>I would love to know what company did that tune up because checking ductwork connections is literally the bare minimum of the job. This is the kind of stuff that gives our whole industry a bad reputation. Guys show up, check the filter, maybe look at the thermostat, collect $89 and leave. That&#8217;s not a tune up that&#8217;s a scam. I&#8217;ve been doing this&hellip;<span class="activity-read-more" id="activity-read-more-8338"><a href="https://hvachub.co/news-feed/p/8335/#acomment-8338" rel="nofollow"> Read more</a></span></p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hwilliams/" data-bb-hp-profile="55" rel="nofollow">Harry</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Customer complaint was one bedroom not cooling. Found this under the house. Flex completely disconnected from the boot, just dumping [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">732c8602eb3f220654770bfaa0d8be5a</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/8174/#acomment-8238</link>
				<pubDate>Sat, 25 Jul 2026 23:47:36 +1200</pubDate>

									<content:encoded><![CDATA[<p>Change the filter, hose the condenser, fix the leak, charge her up. If you want to be super tech recovery your gas, pull compressor and dump oil and refill with oil on the tag, change filter drier, pull you a good vac, charge her up. It&#8217;s in and out on thermal. That oil is toast, might be able to stretch them another season if you oil change it.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/rob_vitale64/" data-bb-hp-profile="45" rel="nofollow">Robert</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> 2019 Bryant 2-ton R410A heat pump. Customer said the compressor made a terrible noise and then quit going. Outdoor fan runs fine, compressor [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ddd9db1d6ef0a1f4f3e7d372f840ba0d</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/8165/#acomment-8202</link>
				<pubDate>Fri, 24 Jul 2026 19:11:56 +1200</pubDate>

									<content:encoded><![CDATA[<p>&#x1f602; it&#8217;s not a badge it&#8217;s just honest.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jackson-hayes/" data-bb-hp-profile="97" rel="nofollow">Jackson</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> If you polled 1000 people in your town and asked them to name three air conditioning companies how many do you think would mention yours?					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">fcb1d6652f4932e1fab3f77b202a33c5</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7828/#acomment-7893</link>
				<pubDate>Thu, 02 Jul 2026 08:10:10 +1200</pubDate>

									<content:encoded><![CDATA[<p>Started building relationships with two different suppliers specifically so I&#8217;m never stuck with just one point of failure. Annoying to manage but worth it.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Anybody else&#8217;s supplier just randomly stop carrying a part you&#8217;ve ordered for years with zero warning? Needed a specific contactor today, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bf11101c57bfdd812bebcceacc6fd6d4</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7828/#acomment-7883</link>
				<pubDate>Thu, 02 Jul 2026 04:24:51 +1200</pubDate>

									<content:encoded><![CDATA[<p>Grainger is pricier though.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Anybody else&#8217;s supplier just randomly stop carrying a part you&#8217;ve ordered for years with zero warning? Needed a specific contactor today, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0564571d20fb78c2c703c397be4bcb43</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7828/#acomment-7834</link>
				<pubDate>Wed, 01 Jul 2026 09:49:17 +1200</pubDate>

									<content:encoded><![CDATA[<p>Amazon has been bailing me out more than my actual supplier lately which feels wrong to say out loud.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jgarcia/" data-bb-hp-profile="66" rel="nofollow">Juan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Anybody else&#8217;s supplier just randomly stop carrying a part you&#8217;ve ordered for years with zero warning? Needed a specific contactor today, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8f1833f057dbfc5d03993911c0e4c301</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7790/#acomment-7793</link>
				<pubDate>Fri, 26 Jun 2026 21:38:46 +1200</pubDate>

									<content:encoded><![CDATA[<p>Engineers drawing duct layouts who&#8217;ve never carried a tin snip is the oldest complaint in this trade and it&#8217;s never not true.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/ethanlewis_12/" data-bb-hp-profile="68" rel="nofollow">Ethan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Whoever specced rectangular duct on this job clearly never had to install it in an 11 foot ceiling with beams every 6 feet. Switched the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">3343c8a803f09c8cc2adcd315ad7461f</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7746/#acomment-7762</link>
				<pubDate>Thu, 25 Jun 2026 05:46:34 +1200</pubDate>

									<content:encoded><![CDATA[<p>GreenSky pulled out of a lot of HVAC partnerships last year. anyone else affected by that.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/alessandro_rossi_88/" data-bb-hp-profile="28" rel="nofollow">Alessandro</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Question on financing. We offer it through Wisetack and Synchrony both. Lately feels like every other call wants financing now, even on [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a13f6758d3ac41dcc01d09ba693441e4</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7630/#acomment-7637</link>
				<pubDate>Wed, 17 Jun 2026 06:06:55 +1200</pubDate>

									<content:encoded><![CDATA[<p>110k. 22 employees 18 vehicles. 5 mil revenue.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/charles_hill_01/" data-bb-hp-profile="38" rel="nofollow">Charles</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> What&#8217;s everyone paying for insurance these days. Workers comp, general liability, commercial auto. Small company, 3 techs, 4 trucks, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">6268e9cabef7154c2c6ae1a5535d4d10</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7397/#acomment-7400</link>
				<pubDate>Tue, 26 May 2026 12:55:45 +1200</pubDate>

									<content:encoded><![CDATA[<p>I&#8217;ve been in this trade 19 years and I still have to remind myself of this when someone questions my price.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/the_dylanparker/" data-bb-hp-profile="9" rel="nofollow">Dylan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Something my mentor told me when I was coming up that I think about a lot.
He said  the customer isn&#8217;t paying for the part. They&#8217;re paying for [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">031cbdc62c4a3f98ca20e2b1eaaa7c9a</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/7112/#acomment-7131</link>
				<pubDate>Thu, 14 May 2026 06:07:51 +1200</pubDate>

									<content:encoded><![CDATA[<p>Our last yard signs lasted one storm season &#x1f605;</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/emiliano_ruiz55/" data-bb-hp-profile="78" rel="nofollow">Emiliano</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Need to order new company shirts, hoodies, equipment stickers and yard signs before things get busy again.
Last batch looked great for about a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">82e5cc1e6058c56adbc1c4c000b671d1</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6775/#acomment-6792</link>
				<pubDate>Wed, 29 Apr 2026 00:15:40 +1200</pubDate>

									<content:encoded><![CDATA[<p>We review pricing every year. Material, fuel, labor, everything has gone up. Even if you don’t want to raise prices, eventually you have to or margins disappear.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/pietro_gallo/" data-bb-hp-profile="48" rel="nofollow">Pietro</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hey,					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f3cad67984c2ec348fa1376c451bef70</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6677/#acomment-6684</link>
				<pubDate>Thu, 16 Apr 2026 20:06:34 +1200</pubDate>

									<content:encoded><![CDATA[<p>If you’re not asking for the job before leaving someone else will.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/grayson_ward/" data-bb-hp-profile="59" rel="nofollow">Grayson</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Quoted a job customer said they’ll  think about it… then you see the same job done a week later by someone else. No feedback, no call back, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">5b238a926fb4eb451f97d0a38500d2b1</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6646/#acomment-6651</link>
				<pubDate>Thu, 16 Apr 2026 01:39:53 +1200</pubDate>

									<content:encoded><![CDATA[<p>0.9 static is already a red flag. Most systems are designed around 0.5 or lower, once you get that high you’re starving the coil and everything shifts superheat climbs, suction drops, and it sends you down the wrong path.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/edwardmitchell_07/" data-bb-hp-profile="80" rel="nofollow">Edward</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Suction 60 psi, superheat 20+, looked like low charge turned out to be airflow. Static was through the roof. Fixed that and everything lined up.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ce29b42d04f17910e503347a2e0ddb35</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6608/#acomment-6633</link>
				<pubDate>Wed, 15 Apr 2026 20:17:16 +1200</pubDate>

									<content:encoded><![CDATA[<p>If you’re pricing it like retail installs you’re not even in the game.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hunterreed_biz/" data-bb-hp-profile="43" rel="nofollow">Hunter</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Trying to get in with a few builders right now and still figuring out my pricing. Feels like I’m coming in too high because I’m not getting [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">bc4873ecf422d429cff6292d584b8854</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6538/#acomment-6548</link>
				<pubDate>Wed, 08 Apr 2026 06:21:30 +1200</pubDate>

									<content:encoded><![CDATA[<p>Everyone can get you leads… until you actually sign the contract.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/fabio_bianchi_53/" data-bb-hp-profile="65" rel="nofollow">Fabio</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Thinking about outsourcing SEO/marketing but hard to tell who actually delivers vs who just sends reports every month. Anyone here had a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">282ae023cb4233fe70e66a17d43636ab</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6538/#acomment-6543</link>
				<pubDate>Wed, 08 Apr 2026 06:17:31 +1200</pubDate>

									<content:encoded><![CDATA[<p>Before chasing more leads, make sure your process can actually handle them.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/fabio_bianchi_53/" data-bb-hp-profile="65" rel="nofollow">Fabio</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Thinking about outsourcing SEO/marketing but hard to tell who actually delivers vs who just sends reports every month. Anyone here had a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">b64811af104e7b3820fece1a5fae03c9</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6248/#acomment-6269</link>
				<pubDate>Wed, 11 Mar 2026 08:31:13 +1300</pubDate>

									<content:encoded><![CDATA[<p>True. Nothing worse than servicing a unit that was dropped on the curb sideways.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucaferrari/" data-bb-hp-profile="50" rel="nofollow">Luca</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> New RTUs just landed for a warehouse changeout. Three units going up on the roof later today. Always a bit of coordination getting the crane [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e53e5834da6635733e07c96c5dcff6ba</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6115/#acomment-6123</link>
				<pubDate>Wed, 18 Feb 2026 02:44:19 +1300</pubDate>

									<content:encoded><![CDATA[<p>Agreed. But it does make the pricing conversation start earlier than it used to.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/m-conti/" data-bb-hp-profile="76" rel="nofollow">Matteo</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Anyone else noticing customers coming in way more “prepared” than before? Not just YouTube stuff I mean price ranges, part numbers, even [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">7766e803cdd32673a921f659e8b97cec</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/6069/#acomment-6077</link>
				<pubDate>Sat, 14 Feb 2026 06:45:00 +1300</pubDate>

									<content:encoded><![CDATA[<p>If it’s flex with tight bends that’ll do it. Guys underestimate how bad crushed flex kills performance.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Had something weird happen today. Didn’t even realize my techs were out here making bets on what the issue would be.
Sent two of them up to [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">869e75666bbf9a397977a22f2e11463c</guid>
				<title>Zachary posted an update in the group HVAC Installation Best Practices: Had something weird happen today. Didn’t even realize my [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/6069/</link>
				<pubDate>Sat, 14 Feb 2026 03:26:25 +1300</pubDate>

									<content:encoded><![CDATA[<p>Had something weird happen today. Didn’t even realize my techs were out here making bets on what the issue would be.<br />
Sent two of them up to look at this unit. I head up a few minutes later and they’re already arguing.<br />
One’s blaming airflow.<br />
Other one’s swearing it’s charge.<br />
Meanwhile the space is still sitting at 82° and nobody’s actually&hellip;<span class="activity-read-more" id="activity-read-more-6069"><a href="https://hvachub.co/news-feed/p/6069/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>11</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">3461d6e55f863bfa4c347ff855e4518b</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5855/#acomment-5873</link>
				<pubDate>Wed, 11 Feb 2026 06:40:21 +1300</pubDate>

									<content:encoded><![CDATA[<p>My favorite is when they ask is that normal? every 30 seconds.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/j_cooper818/" data-bb-hp-profile="13" rel="nofollow">Jordan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> My tech called me laughing today because the customer kept asking what he was doing every step of the way.
Appreciate the interest, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">56cf32c5fe9329c38897b67558daac80</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5820/#acomment-5842</link>
				<pubDate>Tue, 10 Feb 2026 17:33:07 +1300</pubDate>

									<content:encoded><![CDATA[<p>This motor didn’t fail, it was neglected.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/aidencooper/" data-bb-hp-profile="100" rel="nofollow">Aiden</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> This motor’s been making noise for a while.
Guess today was the day it finally quit.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">987b3793bcf15ac3ab879640bab7f346</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/5627/#acomment-5646</link>
				<pubDate>Thu, 05 Feb 2026 16:27:37 +1300</pubDate>

									<content:encoded><![CDATA[<p>You train them, cover for them when they mess up, give them steady work, sometimes even personal help. Then they’re gone overnight. Not even a month notice.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/benking_business/" data-bb-hp-profile="33" rel="nofollow">Benjamin</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Hello All,					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">e43046ac3210fcdeb5f271a65b9a5a32</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4857/#acomment-4866</link>
				<pubDate>Tue, 20 Jan 2026 03:49:15 +1300</pubDate>

									<content:encoded><![CDATA[<p>We can’t fix everything without blowing the budget. Owners don’t want to pay for perfection.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucaswong_professional/" data-bb-hp-profile="41" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> This room has had at least three different contractors work on it over the years.
You can tell where each one stopped caring.
Everyone fixed [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">8e635b4b99dbc7a8b99fb04251667932</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4739/#acomment-4767</link>
				<pubDate>Sat, 17 Jan 2026 09:05:15 +1300</pubDate>

									<content:encoded><![CDATA[<p>That unit looks like it’s one vibration away from early retirement.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/liam_brooks/" data-bb-hp-profile="53" rel="nofollow">Liam</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Opened this unit up today to see how far we can push it.
It’s working, but if it drops mid-week the downtime will hurt more than the repair [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c80f82541fa9c8a271bfe48f1c56b563</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4670/#acomment-4672</link>
				<pubDate>Thu, 15 Jan 2026 03:06:00 +1300</pubDate>

									<content:encoded><![CDATA[<p>Give it time. If it won’t hold under 500 microns after isolation, you’ve still got moisture or a leak.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/lucas_reed/" data-bb-hp-profile="15" rel="nofollow">Lucas</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Pulled vacuum, watched the gauge, and waited.
Some days the numbers cooperate… some days they don’t.					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">b39b01df864ecde2e252416b85fdf012</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/4213/#acomment-4220</link>
				<pubDate>Thu, 01 Jan 2026 20:53:47 +1300</pubDate>

									<content:encoded><![CDATA[<p>Valve movement isn’t the same as capacity change.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/m_carter/" data-bb-hp-profile="93" rel="nofollow">Mathew</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Flow changes immediately when the valve position is adjusted,
but system response doesn’t scale the way it should under load.Feels like [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">dd96adcfe232f348785f7f80638f2513</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3860/#acomment-3871</link>
				<pubDate>Fri, 19 Dec 2025 11:17:40 +1300</pubDate>

									<content:encoded><![CDATA[<p>Check the actual relief setpoint versus what’s assumed in the sequence.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/salvatore_mancini_/" data-bb-hp-profile="42" rel="nofollow">Salvatore</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> Catching intermittent relief valve venting on the condenser with no high-head alarms or trips.
Data looks normal, but something’s clearly slipping [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">48959004e1a8fd27355fcb4881f39e1d</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3768/#acomment-3777</link>
				<pubDate>Wed, 17 Dec 2025 19:00:15 +1300</pubDate>

									<content:encoded><![CDATA[<p>What’s your differential pressure across the valve when it starts hunting?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/alexscott_45/" data-bb-hp-profile="29" rel="nofollow">Alexander</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> Spent half the day chasing a CHW valve that just won’t sit still at low load.
Setpoint isn’t moving, but the valve keeps opening and closing [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">cf313494de90b1af70c4aa17c44c1045</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3574/#acomment-3575</link>
				<pubDate>Thu, 11 Dec 2025 21:48:32 +1300</pubDate>

									<content:encoded><![CDATA[<p>Seen that happen when the static sensor is a little too far from the takeoff. Fan moves fast, sensor reacts slow, VAVs freak out for a few seconds.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jack-moore_15/" data-bb-hp-profile="83" rel="nofollow">Jack</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Seeing a weird one &#8211; when the supply fan ramps up, a few VAV boxes actually lose airflow for a moment.
CFM drops for a couple seconds like [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">53b4377055f31a61e0b216bd5ca87ebe</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3475/#acomment-3483</link>
				<pubDate>Tue, 09 Dec 2025 19:13:13 +1300</pubDate>

									<content:encoded><![CDATA[<p>Yeah, I’m digging into the logic next. Looks like someone layered sequences over the years.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Ran a smoke-control test earlier, and the return fan briefly reversed direction the moment fire mode engaged.
It only flipped for a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">88aad06120599e80e6ef36259d8fb3b3</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3475/#acomment-3481</link>
				<pubDate>Tue, 09 Dec 2025 19:13:11 +1300</pubDate>

									<content:encoded><![CDATA[<p>&#x1f602; exactly… one second of WTF is enough to ruin your whole day.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Ran a smoke-control test earlier, and the return fan briefly reversed direction the moment fire mode engaged.
It only flipped for a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">0d9673166273aabd34da98178af955a1</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3475/#acomment-3479</link>
				<pubDate>Tue, 09 Dec 2025 19:13:09 +1300</pubDate>

									<content:encoded><![CDATA[<p>Good call &#8211; I’ll check the drive and see if anyone left it in hand or override.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Ran a smoke-control test earlier, and the return fan briefly reversed direction the moment fire mode engaged.
It only flipped for a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">969beb2fb1460073bbcb10a6e3d9b442</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3475/#acomment-3477</link>
				<pubDate>Tue, 09 Dec 2025 19:13:08 +1300</pubDate>

									<content:encoded><![CDATA[<p>Agree &#8211; planning to trace every interlock tomorrow. Something isn’t lining up.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Ran a smoke-control test earlier, and the return fan briefly reversed direction the moment fire mode engaged.
It only flipped for a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">d7710e19561766bcc5d2a400aac3c4d0</guid>
				<title>Zachary posted an update in the group HVAC Contractors &#038; Subcontractors: Ran a smoke-control test earlier, and the return fan [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/3475/</link>
				<pubDate>Tue, 09 Dec 2025 19:13:06 +1300</pubDate>

									<content:encoded><![CDATA[<p>Ran a smoke-control test earlier, and the return fan briefly reversed direction the moment fire mode engaged.<br />
It only flipped for a second, but even that’s enough to create a real hazard if there was an actual event.<br />
Everything points to an override or priority conflict somewhere in the fire sequence logic that needs sorting out.</p>
]]></content:encoded>
				
									<slash:comments>8</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">c0bd1bcb19883a762d0565266e51d934</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/3045/#acomment-3050</link>
				<pubDate>Fri, 14 Nov 2025 19:20:52 +1300</pubDate>

									<content:encoded><![CDATA[<p>Ah yes, the “I do what I want” VAV system. Love when buildings have a mind of their own.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/the_dylanparker/" data-bb-hp-profile="9" rel="nofollow">Dylan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-installation-best-practices/" data-bb-hp-group="1" rel="nofollow">HVAC Installation Best Practices</a> Was checking a VAV system today and the static pressure kept jumping all over the place- from 0.9” straight up to 1.6” the moment a few [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">427e04433f3822c1e2e965b373e72c97</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2989/#acomment-2990</link>
				<pubDate>Wed, 12 Nov 2025 19:59:23 +1300</pubDate>

									<content:encoded><![CDATA[<p>Classic 24V ghost. Shows up, kills your voltage, then disappears when the boss walks over.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/j_cooper818/" data-bb-hp-profile="13" rel="nofollow">Jordan</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Came across a strange one today &#8211; transformer keeps dropping voltage under load, but this time the fuse actually holds fine and the [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">269819093e6ac89fdbd4de720c353cc7</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2691/#acomment-2694</link>
				<pubDate>Wed, 29 Oct 2025 13:56:21 +1300</pubDate>

									<content:encoded><![CDATA[<p>We keep losing good technicians to bigger companies that offer specialized training.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/graysonwest_official/" data-bb-hp-profile="103" rel="nofollow">Grayson</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-tools-equipment/" data-bb-hp-group="3" rel="nofollow">HVAC Tools &amp; Equipment</a> If I’m honest, the toughest challenge these days isn’t finding new clients-it’s finding the right technicians.

Commercial systems have changed [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">644fb8485c6aa2ec4ed39675cce121e3</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2654/#acomment-2664</link>
				<pubDate>Sun, 26 Oct 2025 18:32:08 +1300</pubDate>

									<content:encoded><![CDATA[<p>Noted, I’ll check the coil temp next and see if it matches suction readings.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Working on a rooftop unit and noticed suction pressure dropping intermittently even though load and airflow seem fine.
No obvious leaks, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">89f7f45956e37117af7f85d8dc6725d9</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2654/#acomment-2662</link>
				<pubDate>Sun, 26 Oct 2025 18:32:07 +1300</pubDate>

									<content:encoded><![CDATA[<p>Haha! Yep, as soon as you put the gauges on, everything seems fine…</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Working on a rooftop unit and noticed suction pressure dropping intermittently even though load and airflow seem fine.
No obvious leaks, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">1d29d7d443a1626a18175f6f37303c3b</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2654/#acomment-2660</link>
				<pubDate>Sun, 26 Oct 2025 18:32:06 +1300</pubDate>

									<content:encoded><![CDATA[<p>Ah, that might explain it &#8211; system was evacuated last week.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Working on a rooftop unit and noticed suction pressure dropping intermittently even though load and airflow seem fine.
No obvious leaks, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">b9c71889606625d04b67063abc2e9263</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2654/#acomment-2658</link>
				<pubDate>Sun, 26 Oct 2025 18:32:05 +1300</pubDate>

									<content:encoded><![CDATA[<p>Good point &#8211; I’ll inspect the liquid line for any restrictions.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Working on a rooftop unit and noticed suction pressure dropping intermittently even though load and airflow seem fine.
No obvious leaks, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">817c1d6bd358714b5b9bc3ad0c656a89</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2654/#acomment-2656</link>
				<pubDate>Sun, 26 Oct 2025 18:32:03 +1300</pubDate>

									<content:encoded><![CDATA[<p>Thanks! I’ll check the valve next and see if it moves freely.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/zachary1/" data-bb-hp-profile="23" rel="nofollow">Zachary</a> posted an update in the group <a href="https://hvachub.co/groups/hvac-contractors-subcontractors/" data-bb-hp-group="4" rel="nofollow">HVAC Contractors &amp; Subcontractors</a> Working on a rooftop unit and noticed suction pressure dropping intermittently even though load and airflow seem fine.
No obvious leaks, [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">ed9d926c910811683ce3ea63d6906233</guid>
				<title>Zachary posted an update in the group HVAC Contractors &#038; Subcontractors: Working on a rooftop unit and noticed suction [&#133;]</title>
				<link>https://hvachub.co/news-feed/p/2654/</link>
				<pubDate>Sun, 26 Oct 2025 18:32:02 +1300</pubDate>

									<content:encoded><![CDATA[<p>Working on a rooftop unit and noticed suction pressure dropping intermittently even though load and airflow seem fine.<br />
No obvious leaks, and refrigerant charge looks correct.</p>
<p>Could this be a TXV issue, or something else deeper in the system? Anyone experienced similar behavior and figured out the root cause?</p>
]]></content:encoded>
				
									<slash:comments>10</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">435640e75385ba9faa455a7cb74e6196</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2101/#acomment-2104</link>
				<pubDate>Fri, 03 Oct 2025 12:58:18 +1300</pubDate>

									<content:encoded><![CDATA[<p>once installed a thermostat upside down. Client didn’t notice for a week!</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/natcarter/" data-bb-hp-profile="17" rel="nofollow">Nathan</a> posted an update in the group <a href="https://hvachub.co/groups/troubleshooting-repairs/" data-bb-hp-group="2" rel="nofollow">Troubleshooting &amp; Repairs</a> I just had one of those days on the field where everything that could go wrong… went wrong &#x1f605;.

I misread a pressure gauge and didn’t notice a [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a089d665752da6e2354cf9944be7fcc9</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/2082/#acomment-2093</link>
				<pubDate>Fri, 03 Oct 2025 12:58:12 +1300</pubDate>

									<content:encoded><![CDATA[<p>Does automation feel too impersonal for clients?</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/hvac/" data-bb-hp-profile="1" rel="nofollow">HVAC Community Hub</a> posted an update in the group <a href="https://hvachub.co/groups/the-hvac-automation-blueprint/" data-bb-hp-group="6" rel="nofollow">The HVAC Automation Blueprint</a> Hey HVAC pros,

I’ve been thinking a lot about how automation is changing our industry-and honestly, it’s a game-changer. 

One [&hellip;]					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a10c5e98d8f419bbe40fe6df59e3d6cd</guid>
				<title>Zachary posted a new activity comment</title>
				<link>https://hvachub.co/news-feed/p/1921/#acomment-1932</link>
				<pubDate>Tue, 23 Sep 2025 18:36:31 +1200</pubDate>

									<content:encoded><![CDATA[<p>Piece by piece all day. Full overhaul is a headache.</p>
				<strong>In reply to</strong> -
					<a href="https://hvachub.co/members/jamhughes_/" data-bb-hp-profile="73" rel="nofollow">Jameson</a> posted an update in the group <a href="https://hvachub.co/groups/the-hvac-automation-blueprint/" data-bb-hp-group="6" rel="nofollow">The HVAC Automation Blueprint</a> Just sat in on a demo for this full HVAC automation blueprint—scheduling, dispatching, invoicing, the whole nine yards. It looked incredible, [&hellip;]					]]></content:encoded>
				
				
							</item>
		
	</channel>
</rss>
		